— 43 —
LUT (Lookup Table)
The LUT function is used to generate a non-linear mapping between signal values
captured on the sensor and those that are output from the camera.
You can specify the output curve using 257 setting points (indexes).
■
To use the LUT function
Configure the settings as follows.
■
LUT Value
LUT values range from 0 at the lowest to 4095 at the highest. Linear interpolation is
used to calculate LUT values between the index points.
Index0 Index1 Index2
LUTValue[0]
LUTValue[1]
LUTValue[2]
Index256
LUTValue[256]
0
4095
*) Color model only
Item
Setting value /
selectable range
Description
LUTMode
LUT
Use LUT.
LUTSelector* Red, Green, Blue
Select the LUT channel to control.
LUTIndex
0 ~ 256
Select the LUT index to configure. Indexes represent the
possible pixel values captured on the sensor, from the
lowest value (Index 0) to the highest (Index 256). For
example, Index 0 represents a full black pixel and Index
256 represents a full white pixel.
LUTValue
0 ~ 4095
Set the LUT output value for the selected index.
Values between points are determined
using the linear interpolation values of
data to the left and right.
Go-X Series USB3 Vision I/F
Содержание GOX-2402M-USB
Страница 73: ...Go X Series USB3 Vision I F Spectral Response GOX 2402MC USB 73...
Страница 74: ...Go X Series USB3 Vision I F Spectral Response GOX 3200MC USB 74...
Страница 75: ...75 Spectral Response GOX 3201MC USB Go X Series USB3 Vision I F...
Страница 76: ...Spectral Response GOX 5102MC USB Go X Series USB3 Vision I F 76...
Страница 77: ...77 Spectral Response GOX 5103MC USB Go X Series USB3 Vision I F...
Страница 78: ...Go X Series USB3 Vision I F Spectral Response GOX 8901MC USB 78...
Страница 79: ...Go X Series USB3 Vision I F Spectral Response GOX 12401MC USB 79...
Страница 80: ...80 Dimensions Dimenstional tolerance 0 3mm Unit mm Go X Series USB3 Vision I F...