Setting range
Default value
Description
Configure pulse generator settings.
1〜4096
4
Set the division value for the prescaler (12 bit) using PixelClock as the base
clock.
0.0181274〜74.25
0.45
Set the clock used for the pulse generator.
This value is calculated using the [ClockPreScaler] value as a base.
PulseGenerator0
PulseGenerator0
Select the pulse generator.
PulseGeneratorLength
1〜1048575
618750
Set the maximum count-up value as a clock count.
PulseGeneratorLengthMs (ms)
1 / PulseGeneratorClock
(MHz) 〜1048575 /
PulseGeneratorClock (MHz)
33.3333
Set the maximum count-up value in milliseconds.
This value is calculated using the [PulseGeneratorLength] value as a base.
The setting range varies depending on the [ClockPreScaler] value.
PulseGeneratorFrequency (Hz)
PulseGeneratorClock (MHz)
÷ 1048575 x 1000000 〜
PulseGeneratorClock (MHz) x
1000000
30
Set the maximum count-up value as a frequency.
This value is calculated using the [PulseGeneratorLength] value as a base.
PulseGeneratorStartPoint
0 〜 1048574
0
Set the start point of the High interval as a clock count.
When the counter reaches this value, the output will be 1.
PulseGeneratorStartPointMs
(ms)
0 〜 1048575 /
PulseGeneratorClock (MHz)
0
Set the start point of the High interval in milliseconds.
When the counter reaches this value, the output will be 1.
The setting range varies depending on the [ClockPreScaler] value.
PulseGeneratorEndPoint
1 〜 1048575
464063
Set the start point of the Low interval as a clock count.
When the counter reaches this value, the output will be 0.
PulseGeneratorEndPointMs (ms)
1/ PulseGeneratorClock
(MHz) 〜
1048575 /
PulseGeneratorClock (MHz)
25
Set the start point of the Low interval in milliseconds.
When the counter reaches this value, the output will be 0.
The setting range varies depending on the [ClockPreScaler] value.
PulseGeneratorPulseWidth (ms) ー
25
Display the High interval width of the pulse in milliseconds.
The duration between the Start Point and End Point is calculated. The setting range varies
depending on the [ClockPreScaler] value.
PulseGeneratorRepeatCount
0 〜 255
0
Set the repeat count for the counter.
When this is set to [0], a free counter is enabled with no repeat limit.
PulseGeneratorClearActivation
0:Off
1:Rising Edge
2:Falling Edge
3:Level High
4:Level Low
Off
Set the clear signal condition for the count clear input of the pulse generator.
PulseGeneratorClearSource
ー
Low
Select the count clear input signal source.
[Setting range]
0:Low, 1:High, 3:AcquisitionTriggerWait, 4:AcquisitionActive
5:FrameTriggerWait, 6:FrameActive, 7:ExposureActive, 8︓FVAL
14:UserOutput0, 15:UserOutput1, 16:UserOutput2, 17:UserOutput3,
21:Line5, 26:Nand0 Out, 27:Nand1 Out
PulseGeneratorClearSyncMode
0:Async Mode
1:Sync Mode
0:Async Mode
Select the sync mode for the count clear input signal.
g) PulseGenerator
PulseGeneratorClock (MHz)
ClockPreScaler
Item
PulseGeneratorSelector
—
63
—
Go-X Series USB3 Vision I/F
Содержание GOX-2402M-USB
Страница 73: ...Go X Series USB3 Vision I F Spectral Response GOX 2402MC USB 73...
Страница 74: ...Go X Series USB3 Vision I F Spectral Response GOX 3200MC USB 74...
Страница 75: ...75 Spectral Response GOX 3201MC USB Go X Series USB3 Vision I F...
Страница 76: ...Spectral Response GOX 5102MC USB Go X Series USB3 Vision I F 76...
Страница 77: ...77 Spectral Response GOX 5103MC USB Go X Series USB3 Vision I F...
Страница 78: ...Go X Series USB3 Vision I F Spectral Response GOX 8901MC USB 78...
Страница 79: ...Go X Series USB3 Vision I F Spectral Response GOX 12401MC USB 79...
Страница 80: ...80 Dimensions Dimenstional tolerance 0 3mm Unit mm Go X Series USB3 Vision I F...