Setting range
Default value
Description
Configure counter settings.
(This camera only supports counter functions.)
0:Counter0, 1:Counter1,
2:Counter2, 3:Counter3
ー
Select the counter.
CounterEventSource
ー
Off
Assign the counter event signal for which you want to read the count value to
a dedicated counter, and read the value.
Counter0 0:Off, 1:FrameTrigger
Counter1 0:Off, 3:SensorReadOut
Counter2 0:Off, 2:ExposureStart
Counter3 0:Off, 4:FrameTransferEnd
CounterEventActivation
ー
ー
Set the count timing.
The setting value is fixed with the following data.
Counter0:RisingEdge, Counter1:RisingEdge, Counter2:RisingEdge, Counter3:FallingEdge
CounterReset
ー
ー
Reset the counter.
CounterRefresh
0〜65535
0
Update the count value.
CounterValue
0〜65535
0
Display the count value.
CounterStatus
ー
ー
Display the counter status.
0:CounterIdle: Idle
2:CounterActive: Counting
4:CounterOverflow: Count value exceeded the mazimum value
Configure chunk control settings.
True, False
False
Set whether to enable ChunkData.
ー
ー
The value of OffsetX (ChunkID 2000h : DataType Integer)
ー
ー
The value of OffsetY (ChunkID 2001h : DataType Integer)
ー
ー
The value of Width (ChunkID 2002h : DataType Integer)
ー
ー
The value of Height (ChunkID 2003h : DataType Integer)
ー
ー
The value of LineStatusAll (ChunkID 2013h : DataType Integer)
The value of ExposureTime (ChunkID 2004h : DataType Integer)
ー
ー
The value of AnalogGainAll (ChunkID 201Fh : DataType Float)
ー
ー
The value of DigitalGainRed (ChunkID 2006h : DataType Float)
ー
ー
The value of AnalogGainBlue (ChunkID 2007h : DataType Float)
ー
ー
The value of FrameTriggerのCounter (ChunkID 200Eh : DataType Integer)
ー
ー
The value of SequencerSetActive (ChunkID 200Ch : DataType Integer)
0〜10000
0
PendingAck function test command.
The camera waits for TestPendingAck (ms) time and returns an Ack response.
Configure user settings.
Default, UserSet1,
UserSet2, UserSet3
Default
Select the user settings.
UserSetLoad
0(default), 1, 2, 3
ー
Load user settings.
(If 0 is specified, the factory default setting is read.)
UserSetSave
1,2,3
ー
Save the current setting values as user settings.
UserSetSelector
q) TestControl
CounterSelector
o) CounterAndTimerControl
ChunkFrameTriggerCounter
Item
ChunkWidth
ChunkHeight
ChunkGainAnalogBlue
ChunkSequencerSetActive
ChunkOffsetY
ChunkGainAnalogAll
ChunkModeActive
ChunkGainDigitalRed
ChunkLineStatusAll
ChunkExposureTime
ChunkOffsetX
r) UserSetControl
p) ChunkDataControl
TestPendingAck (ms)
—
67
—
Go-X Series USB3 Vision I/F
Содержание GOX-2402M-USB
Страница 73: ...Go X Series USB3 Vision I F Spectral Response GOX 2402MC USB 73...
Страница 74: ...Go X Series USB3 Vision I F Spectral Response GOX 3200MC USB 74...
Страница 75: ...75 Spectral Response GOX 3201MC USB Go X Series USB3 Vision I F...
Страница 76: ...Spectral Response GOX 5102MC USB Go X Series USB3 Vision I F 76...
Страница 77: ...77 Spectral Response GOX 5103MC USB Go X Series USB3 Vision I F...
Страница 78: ...Go X Series USB3 Vision I F Spectral Response GOX 8901MC USB 78...
Страница 79: ...Go X Series USB3 Vision I F Spectral Response GOX 12401MC USB 79...
Страница 80: ...80 Dimensions Dimenstional tolerance 0 3mm Unit mm Go X Series USB3 Vision I F...