User Manual (Ver. 2.0) - Main Functions
GO-5000M-PMCL | GO-5000M-PMCL-EP | GO-5000M-PMCL-UV
- 89 -
Gain Raw
The range for adjustment: Gain Raw Digital All: 100 ~ 1600 (0dB ~ 24dB)
This provides automatic control of the gain level.
Gain Auto
This provides automatic control of the gain level. This is controlled by the command JAI ALC
Reference.
l
OFF: Adjust manually.
l
Continuous: Operate the auto gain continuously.
The following detailed settings are also available.
l
ALC Speed: The rate of adjustment of GainAuto can be set (common with Exposure Auto)
l
Gain Auto Max: The maximum value of GainAuto control range can be set
l
Gain Auto Min: The minimum value of GainAuto control range can be set
l
ALC Reference: The reference level of Gain Auto control can be set (common with Exposure
Auto)
l
ALC Area Selector: The measurement area of GainAuto control can be set. (Common with
Exposure Auto)
l
ALC Area Enable: Determine the use of selected ALC area. This can enable its use area by
area. If ALC Area Enable All is set to “True”, all areas are enabled. In this case, the setting area
by area is disabled.
ALC Channel Area