User Manual (Ver. 2.0) - Short ASCII Command List
GO-5000M-PMCL | GO-5000M-PMCL-EP | GO-5000M-PMCL-UV
- 114 -
Name
Access
Short
ASCII
Values
MIN MAX Default
Description
SequenceROI Vbinning1 R/W
SQVB2
1: Vbinning = OFF
2: Vbinning = x2
4: Vbinning = x4
1
4
1
SQVB2=[Param.]<CR><LF>
SQVB2?<CR><LF>
SequenceROI Vbinning2 R/W
SQVB3
1: Vbinning = OFF
2: Vbinning = x2
4: Vbinning = x4
1
4
1
SQVB3=[Param.]<CR><LF>
SQVB3?<CR><LF>
SequenceROI Vbinning
(n-1)
R/W
SQVB(n)
1: Vbinning = OFF
2: Vbinning = x2
4: Vbinning = x4
1
4
1
SQVB(n)=[Param.]<CR><LF>
SQVB(n)?<CR><LF>
SequenceROI
Vbinning127
R/W
SQVB128
1: Vbinning = OFF
2: Vbinning = x2
4: Vbinning = x4
1
4
1
SQVB128=[Param.]<CR><LF>
SQVB128?<CR><LF>
SequenceROI
LutEnable0
R/W
SQLUT 1
Off/On
0
1
0
SQLUT1=[Param.]<CR><LF>
SQLUT1?<CR><LF>
SequenceROI
LutEnable1
R/W
SQLUT 2
Off/On
0
1
0
SQLUT2=[Param.]<CR><LF>
SQLUT2?<CR><LF>
SequenceROI
LutEnable2
R/W
SQLUT 3
Off/On
0
1
0
SQLUT3=[Param.]<CR><LF>
SQLUT3?<CR><LF>
SequenceROI LutEnable
(n-1)
R/W
SQLUT(n) Off/On
0
1
0
SQLUT(n)=[Param.]<CR><LF>
SQLUT(n)?<CR><LF>
SequenceROI
LutEnable127
R/W
SQLUT128 Off/On
0
1
0
SQLUT128=
[Param.]<CR><LF>
SQLUT128?<CR><LF>
SequenceROI
BlackLevel0
R/W
SQBL1
Min ~ Max
-256 255
0
SQBL1=[Param.]<CR><LF>
SQBL1?<CR><LF>
SequenceROI
BlackLevel1
R/W
SQBL2
Min ~ Max
-256 255
0
SQBL2=[Param.]<CR><LF>
SQBL2?<CR><LF>
SequenceROI
BlackLevel2
R/W
SQBL3
Min ~ Max
-256 255
0
SQBL3=[Param.]<CR><LF>
SQBL3?<CR><LF>
SequenceROI
BlackLevel(n-1)
R/W
SQBL(n)
Min ~ Max
-256 255
0
SQBL(n)=[Param.]<CR><LF>
SQBL(n)?<CR><LF>
SequenceROI
BlackLevel127
R/W
SQBL128
Min ~ Max
-256 255
0
SQBL128=[Param.]<CR><LF>
SQBL128?<CR><LF>
CommnadSequence
Index
R/W
CSQI
Same as Sequence
Mode Index
0
9
0
CSQI=[Param.]<CR><LF>
CSQI?<CR><LF>
CurrentSequence Index
R/O
SQIDX
Same as Sequence
Mode Index
0
9
0
SQIDX?<CR><LF>
SequenceReset
W/O
SQRST
0
0
0
0
SQRST=[Param.]<CR><LF>