User Manual (Ver. 2.0) - Main Functions
GO-5000M-PMCL | GO-5000M-PMCL-EP | GO-5000M-PMCL-UV
- 77 -
Normal Continuous Operation
This is used for applications which do not require triggering.
Trigger Mode
Readout Mode
Time (Min. Frame Period)
Timed Exposure Mode
Trigger Mode OFF*
Full
9435us
AOI Center 2/3
6281us
AOI Center 1/2
4740us
AOI Center 1/4
2393us
AOI Center 1/8
1219us
V Binning ON (Full)
4740us
Minimum interval (1X8–1Y, 8-bit, CL Clock =72.85MHz)
Note: