User Manual (Ver. 2.0) - Main Functions
GO-5000M-PMCL | GO-5000M-PMCL-EP | GO-5000M-PMCL-UV
- 76 -
Trigger Source
Select the trigger source to be used for trigger operation (Frame Start) from the following:
Trigger Source
Item
Description
Low
Connect LOW level signal to the selected trigger operation (Default setting)
High
Connect HIGH level signal to the selected trigger operation
Soft Trigger
Connect Soft Trigger signal to the selected trigger operation. Trigger can be input manually
by the execution of the software trigger. Trigger software is available on each trigger
source.
PulseGenerator0 Connect Pulse generator 0 signal to the selected trigger operation
Line 7 – CC1
Connect Trigger In signal through CC1 in Camera Link Interface to the selected trigger
operation
NAND 0 Out
Connect NAND 0 OUT signal to the selected trigger operation
NAND 1 Out
Connect NAND1 OUT signal to the selected trigger operation
Trigger Activation
This command can select how to activate the trigger.
l
Rising edge
: At the rising edge of the pulse, the trigger is activated.
l
Falling edge
: At the falling edge of the pulse, the trigger is activated.
l
Level High
: During the high level of trigger, the accumulation is activated
l
Level Low
: During the low level of trigger, the accumulation is activated
If Exposure Mode is set to Trigger Width, Level High or Level Low must be used.
Trigger Activation Setting
Exposure Mode
Rising Edge
Falling Edge
Level High
Level Low
Timed
✓
✓
Trigger Width
✓
✓
Timed RCT
✓
✓
✓
: Supported
Empty: Not Supported