JIF-2002 WEIGHING INDICATOR&CONTROLLER
49
7. When the display reaches "
Final - Free
", the
Free
Output (Pin 10) signal
will come
OFF
. Closed the Dribble-Flow Gate by using the Free Output
OFF signal.
8. Batch Finish signal is sent after the set time period (F103) or when the
display is stable.
9. After Free Fall has stopped - check to see if the HI and LO (Pin 9, 8)
signals are OFF. If both outputs are OFF then the batch is completed
correctly.
10. Automatic Free Fall is now recalculated for the next event.
11. The Weighing Hopper Discharge Gate will be opened using the Finish
Output (Pin7) ON signal.
12. Data Output is sent (Auto print Mode: BCD, RS-232C, RS-422/485,
Printer or Current Loop). The NET Weight data will be accumulated.
13. Ready for the next batching event.
14. If an Abort signal is sent (Pin 21) anytime after the Start signal is
received,
then:
(1) SP 1, SP 2 and Free signals will go OFF, and Gates will be closed.
(2) Batch Finish and Data Output signals will be sent.
(3) NET Weight data will be accumulated.