JIF-2002 WEIGHING INDICATOR&CONTROLLER
12
3-4 Quick Function Table
◎
WEIGHT FUNCTION TABLE
F 000
Decimal Point
Adjustment
0
No Decimal
1
1 Decimal
2
2 Decimal
3 Decimal
4
4 Decimal
F 001
Weighing Unit
Selection
0
None Kilogram
2
Pound
F 002
Display
Update rate
1
10 times/Sec 20 times/Sec
3
40 times/Sec
F 003
Digital Filter
0
∼
7 step digital filter
F 004
Set Zero
Range
1
±
5%
±
10%
3
±
20%
4
±
30% of Max. Capacity
F 005
Motion
Detection
0.5 SEC 1 DIV
∼
1 SEC 18 DIV 16 Steps (00 Stable)
F 006
Automatic
ZERO
Tracking
Compensation
1 SEC 0.5 DIV
∼
2 SEC 4.0 DIV 16 Steps (00 OFF)
F 007
ZERO &
TARE keys
Availability
ZERO & TARE keys always work
1
only work
when display is STABLE
F 008
TARE Key
Availability
TARE key always work
1
If the GROSS is
Negative (-), TARE key does not work
F 009
Accumulation
Availability
0
OFF
1
Stable
2
Manual
Control Input Command Accumulation
◎
20 mA Current Loop STANDARD
F C00
Data type
Same as display
2
Gross Weight
3
NET Weight
4
TARE Weight
5
Gross Weight, NET Weight, TARE Weight
F C01
Output Mode
Stream
2
Stable and auto print
3
Manual print
mode
4
Accumulate and print
F C02
Output Format
Sending without set point Code
1
Sending with set point Code
Содержание JIF-2002
Страница 1: ...JIF 2002 WEIGHING INDICATOR CONTROLLER 1 CHAPTER 1 INTRODUCTION ...
Страница 5: ...JIF 2002 WEIGHING INDICATOR CONTROLLER 5 CHAPTER 2 INSTALLATION ...
Страница 9: ...JIF 2002 WEIGHING INDICATOR CONTROLLER 9 CHAPTER 3 SPECIFICATIONS ...
Страница 17: ...JIF 2002 WEIGHING INDICATOR CONTROLLER 17 CHAPTER 4 SYSTEMFUNCTIONS ...
Страница 41: ...JIF 2002 WEIGHING INDICATOR CONTROLLER 41 CHAPTER 5 SET POINTS ...
Страница 54: ...JIF 2002 WEIGHING INDICATOR CONTROLLER 54 CHAPTER 6 OPTIONS ...