26
JAUTP / JAUTPS CONTROLLER
11.2 GLOSSARY OF ALERT MESSAGES
CLEANER CANNOT BE TURNED ON WHILE SPA
IS ON
This message is displayed if the pool cleaner is activated
when in spa mode and water is circulating to the spa.
The pool cleaner requires that water be circulating
to the pool in order for it to operate. Return to pool
mode to activate the cleaner.
CLEANER CANNOT BE TURNED ON WHILE
SPILLOVER IS ON
The return valve has been rotated to the spa position
to give the spa spillover effect.
FREEZE PROTECT
This message indicates that freezing conditions have
been detected by the freeze protection sensor, and that
equipment assigned to freeze protection are active (for
example, the filter pump).
See Freeze Protection Menu
for
more information.
NOTE
:
The filter pump is always protected; spa and
auxiliary circuits can be assigned to freeze pro-
tection. If a freeze protected Auxiliary is turned
off during freeze protection, a message will be
displayed indicating that item is off but will turn
on in X amount of minutes. The minutes will
vary depending on how long freeze mode has
been active from one (1) to 15 minutes.
SENSOR OPEN
This error message indicates that the sensor is not
installed properly or is malfunctioning. Call your pool
service person to resolve this problem.
NOTE
:
If the message reads WATER TEMP OPEN, the
heater will not fire. If message
AIR TEMP OPEN
is displayed, freeze protection will not operate
correctly.
POOL HEATER ENABLED
This message indicates that the pool heater is ready to
use but is not actually firing. The filter pump must be on,
and the water temperature must be below the setting
for the heater to fire.
PUMP WILL REMAIN ON WHILE SPILLOVER IS
ON
This message is displayed when you attempt to turn
off the filter pump while a spa spillover is on. Since the
filter pump is necessary for spillover operation, the
pump will remain on until the spillover is turned off.
PUMP WILL TURN OFF AFTER COOL DOWN
CYCLE
This message indicates that the filter pump is circulating
water to cool down the heater. The filter pump will
continue to run for five minutes to protect the heater
from damage, whenever the heater has fired and has
been off for less than five (5) minutes.
PUMP WILL TURN ON AFTER DELAY
This message is displayed during pool/spa switching.
The JAUTPS/JAUTP waits 35 seconds while the valves
turn from pool position to spa position (or vice-versa)
before activating the filter pump.
SERVICE MODE
Service mode is used by the pool service person to aid
them in servicing the pool.
SENSOR SHORT
This error message indicates that the sensor is not
installed properly or is malfunctioning. Call your pool
service person to resolve this problem.
NOTE
:
If the message reads WATER TEMP SHORT, the
heater will not fire. If the message AIR TEMP
SHORT is displayed, freeze protection will not
operate correctly.