16
J-445/J-435 Export
Figure D
(Terminal Block 230V/50z Wire Connection)
[refer to pages 69 and 69 for wiring diagram]
*IMPORTANT NOTE:
Wire connections on controller board must be
changed depending on the number of breakers being used, pages 71
Service 1
Brn (L1)
Blu (N1)
BREAKER TERMINAL CONNECTIONS
L1 = All Components
Blu Brn
(N1)
(L1)
TB1
TB3
Green
Factory Default
Blu
Blu
Brn
Brn
Green
(L1)
(L2)
(N1)
(N2)
TB1
TB3
Blu
Brn
Brn
Brn
Green
(L1)
(L2)
(N1)
(L3)
TB1
TB3
Service 1
Service 2
Brn (L2)
Brn (L1)
Blu (N2)
Blu (N1)
BREAKER TERMINAL CONNECTIONS
L1 = Heater and transformer
L2 = All other components
Service 1
Service 2
Service 3
Brn (L2)
Brn (L3)
Brn (L1)
Blu (N1)
BREAKER TERMINAL CONNECTIONS
L1 = Heater and transformer
L2 = Pump 1 and other components
L3 = Pump 2