J-445/J-435 Export
B.
Configuration settings
Single Service (default setting):
1x16A
This setting will turn the heater off any time the jets
pump is activated.
1x20A
This setting will turn the heater off any time either one of
the pumps are activated on two pump models.
1x32A
This setting is for all two pump model spas. Both pumps
and the heater will be allowed to operate at the same
time.
Dual Service:
2x16A
Both the jets pump and the heater will be allowed to
operate at the same time.
1x16A/1x20A This setting is for all two pump model spas. Both pumps
and the heater will be allowed to operate at the same
time.
Three Phase Service:
3x16A
This setting is for all two pump model spas. Both pumps
and the heater will be allowed to operate at the same
time.
17.3 Single Service 50Hz Connection
Wiring for export models with a single service breaker. The jumper wiring
is shown below. The included extra White wire (1*)
must
be installed.
This is the factory default.
TB1
D
C
B
A
J51
J49
J59
J44
J37
J38
J53
J45
J46
J47
J41
J58
J42
J31
J32
J33
J40
J64
J36
J35
1
2
3
4
GRN
L1 BRN
N1 BLU
SINGLE
SERVICE
1
2
4
3
BREAKER TERMINAL
CONNECTIONS
L1 = All Components
Single Service Jumper Wiring
Wire
From
To
1*
J33
J47
2
J37
J36
3
J46
J51
4
J59
J41
*Install extra white wire at
these jumpers