PhaseStation 53100A User’s Manual V1.04 25-Apr-2022
92
When used in the
Measurement
→
Frequency difference (
f
)
view, the effect of
Trace
→
Phase/frequency traces begin at zero (
z
)
is somewhat similar to applying
Edit
→
Subtract global linear phase trend (frequency offset) (
Ctrl-o
)
to each visible plot.
It’s not
quite
the same, though, because a trace’s first data point is not necessarily
anywhere near its trend line. Subtracting the trend will often do a better job at
centering individual traces symmetrically about the Y axis, as seen below.
Of course,
Edit
→
Subtract global linear phase trend (frequency offset) (
Ctrl-o
)
has the
drawback of altering the selected plot’s phase data record and removing potentially
useful information (namely the phase trendline). Fortunately, there’s also a non-
destructive global option that has the same visual effect,
Trace
→
Show linear
phase/frequency residual (
r
)
:
These two commands,
Show linear phase/frequency residual (
r
)
and
Phase/frequency
traces begin at zero (
z
)
, are among the most commonly-used options on the
Trace
menu. If you spend much time working with phase- and frequency-difference traces,
their
r
and
z
keyboard shortcuts will quickly become familiar.
z
can increase visible
detail while preserving the graph’s original shape, while
r
is better at revealing short-
term noise and other effects that become harder to spot as the graph expands to
Figure 39: Linear trend subtracted from the phase data
Figure 40: Viewing the removed trend without altering the data
Содержание PHASE STATION 53100A
Страница 1: ...TM 53100A Phase Noise Test Set User s Manual Revision 1 04 April 25 2022...
Страница 16: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 16...
Страница 18: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 18...
Страница 20: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 20...
Страница 30: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 30...
Страница 36: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 36...
Страница 42: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 42...
Страница 64: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 64...
Страница 74: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 74...
Страница 104: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 104...
Страница 116: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 116...
Страница 122: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 122...
Страница 130: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 130...
Страница 140: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 140...
Страница 143: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 143 Figure 66 5 MHz residual phase noise and AM noise...
Страница 214: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 214...
Страница 215: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 215 Appendix Legal and regulatory notices...