PhaseStation 53100A User’s Manual V1.04 25-Apr-2022
106
High contrast (
C
)
This command toggles the display between normal and high-contrast rendering. The
latter option may be desirable when saving screenshots for publications or Web pages
whose color fidelity may not be sufficient to reveal details in the plot such as minor
graticule lines.
Set spot cursor positions (
j
)
This command opens a dialog box similar
to the one shown at right, allowing the
spot cursor and phase noise integration
limit cursors to be placed at specific
locations.
The spot cursor may be enabled for
display by selecting the “Spot Cursor”
field in the
Legend
menu. While it is
normally placed by left-clicking within
the graph area,
Dis
play→Set spot cursor
positions (
j
)
allows you to specify its
location more precisely, as well as to place it at offsets not normally permitted (such as between
minor divisions on the phase noise and AM noise graticules.) Alternatively, left-clicking on the
graph while the spot cursor is turned off will issue a prompt to enable it.
Refer to the mouseover help text in the dialog box for more information.
Show numeric tables (
Ctrl-n
)
The
numeric table
appears to the right of the graph area in each measurement view,
unless toggled off with this command. The format of the table is different for each
measurement type. In the Allan deviation and other statistical views, a chart displays
the sigma(tau) values at assorted tau intervals. In the
Measurement
→
Frequency
difference (
f
)
view, both drift/trend statistics and a high-precision frequency-count chart
are displayed, while only the former is available in the
Measurement
→
Phase difference
Figure 53: Contrast adjustment
Figure 54
Содержание PHASE STATION 53100A
Страница 1: ...TM 53100A Phase Noise Test Set User s Manual Revision 1 04 April 25 2022...
Страница 16: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 16...
Страница 18: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 18...
Страница 20: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 20...
Страница 30: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 30...
Страница 36: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 36...
Страница 42: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 42...
Страница 64: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 64...
Страница 74: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 74...
Страница 104: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 104...
Страница 116: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 116...
Страница 122: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 122...
Страница 130: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 130...
Страница 140: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 140...
Страница 143: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 143 Figure 66 5 MHz residual phase noise and AM noise...
Страница 214: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 214...
Страница 215: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 215 Appendix Legal and regulatory notices...