REV 3-23-22
10
Programming:
The below timer pictured is the standard SSAC model that allows the end user to select the "coins to start" and
the “total time" by settings series of dip switches. The number of "coins to start" dip switch is how many quarters
are needed to make the machine come on. In the below example, the "one coin" dip is selected which makes the
unit come on with one coin. The "total time" will then need to be set, but a good rule of thumb would be 4 minutes
which requires dip switches 3.2 and .8 to be set to on. This scenario means 1 quarter will provide 4 minutes of
vacuum time. The total time can always be changed by adding or subtracting time. If the operator would later
decide to increase the cost of the unit to "2" quarters, the 2 dip switch would need to be in the on position (all
others off) and the time dip switches would still be 3.2 and .8 dips selected for 4 minutes. Timer is non
accumulating so "coins to start" setting is just to make the machine come on time and "time" is total time
regardless of coins to start.
Time in minutes dip switch settings:
0.2 = 12 seconds
0.4 = 24 seconds
0.8 = 48 seconds
1.6 = 96 seconds
3.2 = 192 seconds
6.4 = 384 seconds
Coins to start
Total time
(non accumulating)