DISCONNECT POWER BEFORE SERVICING OR TROUBLESHOOTING!
REV 3-23-22
13
WHEN PERFORMING MAINTENANCE OR TROUBLE-SHOOTING, TURN POWER OFF!
QUALIFIED PERSONNEL ONLY!
Check key components to isolate failure:
Capacitor:
it is possible the capacitor has
failed and will not start motor. Change if
necessary.
Timer:
Verify proper input voltage. Activate
timer. If no output voltage is present when
timer should be active, replace timer.
Coin mech:
If using a mechanical coin
mech, remove the wires leading to the timer
from the coin mech and tap them together
one time for each coin necessary to start the
timer. If machine starts, replace the coin
mech.
Fuse:
some units contain an in-line fuse.
Check this to make sure power is getting
through. Replace if necessary.
Is source water turned on and not frozen?
Turn on water to system and make sure
temperature is above 32 deg.
Is water solenoid getting power from timer?
If getting power from timer, replace solenoid.
Unit will not start
Possible component failure
Unit will not dispense
water (water
machines only).