Firebrick installation on the pipes (suite)
3.
Insert the rockwool over the bricks and check from the hole
in the hub that the smoke path is not obstructed. There
must be 1 inch (2.54 cm) or more between the rockwool
and the deflector.
4.
Put the two half-round steel plates over the rockwool near
the rear deflector already in place. Be sure to put them
under the rear deflector to maximise the clearance between
the rockwool and the rear deflector. Make sure the
rockwool is not obstructing the space by looking under the
cooking lid on the hub.
WARNING:
Obstructing the smoke path under the deflector
can force smoke to exit by the door when it’s open and it
will cause the stove not to work properly.