61
Ma
in
te
n
an
c
e
Clean the retainer or replace it with a new one. Apply grease (Dow Corning Toray MO-
LYKOTE
®
HP-500) on its surface and screw burning protective agent to the shaft of a
new diaphragm.
Fit a new diaphragm and the retainer into the pump shaft.
Slide the retainer, dome end
fi
rst, onto the diaphragm shaft. And then screw the shaft into the pump
shaft and tighten it until bottoms out and will not turn further.
NOTE
If it is
fi
tted loose, failure may result.
Retract the pump shaft by keypad operation.
Push the Enter key.
Select "Diaphragm Pos." and push the Enter key.
Select "MAX IN Pos." by the right and left keys.
Push the Enter key.
The diaphragm contracts and "MAX IN Pos."
fl
ashes.
Mount the pump head.
Tighten the bolts evenly to 12N•m for the C150 or 3.5N•m
for the C060 in diagonal order.
NOTE
Check the pump shaft has contracted to the full
before mounting the pump head, or a leak or damage
may result.
Wear part replacement
6
7
8
9
Содержание IX-C060 S6 FA-RF
Страница 49: ...49 Operation Language selection Operation programming...
Страница 82: ...82...