37
Ope
ra
tio
n
Operation programming
The pump operation is programmed and controlled by a control unit in different ways at each
operation mode.
Mode
Parameters
Setting ranges
Default
Mode selection
-
MAN/EXT
MAN
External control
Analogue control
0-20mA/ 4-20mA/ 20-0mA/ 20-4mA
4-20mA
Pulse control
0.01560mL/PLS-300mL/PLS (C150)
0.01560mL/PLS
0.00625mL/PLS-120mL/PLS (C060)
0.00625mL/PLS
Batch control
15.6mL/PLS-300L/PLS (C150)
15.6mL/PLS
6.25mL/PLS-120L/PLS (C060)
6.25mL/PLS
Interval Batch control
0-9day, 0-23Hr, 1-59min
0D : 0H : 1M
15.6mL-300L/PLS (C150)
6.25mL-120L/PLS (C060)
15.6mL/PLS
6.25mL/PLS
Pro
fi
bus control
Address : 1-127
50
Signal input
STOP
Closed = Pump OFF/ Closed = Pump ON Closed = Pump OFF
PreSTOP
Closed = Pump OFF/ Closed = Pump ON Closed = Pump OFF
Interlock
Closed = Pump OFF/ Closed = Pump ON Closed = Pump OFF
Leak detection
Enable/ Disable
Enable
Alarm
Alarm 1
STOP/ Pre-STOP/ Interlock
Leak Detection/ Motor Overload
Leak Detection
Alarm 2
STOP/ Pre-STOP/ Interlock
Leak Detection/ Motor Overload
Interlock
Others
Suction speed
100%/ 75%/ 50%/ 25%
100%
AUX speed
200mL/H-150L/H (C150)
150L/H
80mL/H-60.0L/H (C060)
60.0L/H
Diaphragm position
MAX OUT Pos./ MAX IN Pos.
MAX OUT Pos.
Anti-Chattering
1msec/ 2msec/ 5msec
5msec
Unit
Liter/ US gallon
Liter
* A value increases/decreases step by step every time the UP/DOWN keys is pushed. Press and hold either key for quick
change.
Operation programming