Operational functions
■
STOP function (See page 42)
The start/stop of operation can be controlled by a signal from a level sensor.
See page 30 "STOP signal" for wiring diagram.
Example of use: Liquid level monitoring
The pump stops when liquid has fallen below the minimum level.
■
Pre-STOP function (See page 42 & 43)
Liquid level in a supply tank can be monitored by a signal from a level sensor. See page 30 for wiring diagram.
The operation LED changes from green to orange colour when the pump is receiving the Pre-STOP signal
from a level sensor in operation. See page 30 "STOP signal" for wiring diagram.
Example of use: Liquid level monitoring
The operation LED lights in orange colour to inform a user that
liquid comes close to the minimum level in a supply tank.
LED lights
in orange.
Pre STOP signal
Pump ON
Level sensor
Liquid is near the minimum level.
Flow
STOP signal
Pump OFF
Level sensor
Flow
Liquid is below the minimum level.
LED lights
in red.