Piping layout
Flooded suction application
Suction lift application
NOTE
• A suction line bore should be wider than the inlet bore of the pump.
• Flooded suction is recommended when handling a gaseous liquid such as sodium hypochlorite or high-vis-
cosity liquid.
• Observe the permitted force of 100N and moment of 10N•m to the inlet and outlet of the pump head. Support
your piping system as necessary so as not to go over the allowable moment.
Pipework
Accumulator/Chamber
Pump
Relief valve
Pressure valve
Air vent/drain valve
Calibration
cylinder
Tank
Relief valve
Accumulator/Chamber
Pump
Pressure valve
Calibration
cylinder
Air vent/
drain valve
Tank