31
Ins
tal
lation
■
AUX signal
To activate AUX function, connect signal wires to the AUX terminal via the DIN 5-pin connection.
When using an open collector...
Pay attention to polarity. AUX (3) is plus (+), and COM (4) is minus (-).
When using a no-voltage contact...
Use a mechanical relay designed for an electronic circuit. Its minimum application load should be 5mA or less.
1 : N.C. (Brown)
2 : N.C. (White)
3 : AUX (Blue)
4 : COM (Black)
5 : 12VDC30mA or below (Green)
* Each wire is coloured as above for our optional cable. The terminal 5 is an output
and is not used. Do not short-circuit this terminal to COM (4).
■
Output signal
To transmit signal to an external device, connect signal wires to the OUT terminal via the DIN 4-pin connection.
Alarm1<Mechanical relay>: Enable or disable STOP, Pre-STOP, Interlock, Motor overload and Leak
detection individually.
*Leak detection only is enabled at factory default setting.
Alarm2<PhotoMOS relay>: Enable or disable STOP, Pre-STOP, Interlock, Motor overload and Leak
detection individually.
*Interlock only is enabled at factory default setting.
1 : Alarm1 (White)
2 : Alarm1 (Brown)
3 : Alarm2 (Black)
4 : Alarm2 (Blue)
* Each wire is coloured as above for our optional cable.
Mounting direction of the output signal cable
Mount the DIN square connector cable in the following direction and secure it with a M3 screw.
3
2
4
5
1
Wiring for
AUX function
1
2
3
4
Wiring
Output signal cable
M3 screw