Ivoclar Vivadent Programat CS Скачать руководство пользователя страница 10

10

2.1.6

 Contraindication

Never use the furnace without a 
firing table.

2.1.7

 Contraindication 

Firing trays must not be placed in 
the area surrounding the firing 
table, since this will obstruct the 
closing of the furnace head. 

2.1.8

 Contraindication 

Foreign objects must not be  
placed on the furnace head or the 
air vents. Make sure that no liq-
uids or other foreign objects enter 
the air vents, since this may result 
in an electrical shock.

2.1.9

 Contraindication 

Make sure that no liquids or other 
foreign objects enter the furnace.

 

2.1.10

 Contraindication 

Do not insert any foreign objects 
into the air vents. There is a risk of 
electrical shock.

2.1.11

 

Risks of burn hazard 

Never place objects in the firing 
chamber by hand, since there is a 
burn hazard. Always use the tongs 
(accessories) supplied for this pur-
pose. Never touch the hot surface 
of the furnace head, as there is a 
burn hazard. Please also refer to 
the warnings on the furnace. 

 

2.1.12

 

 

Risk of crushing and burn hazard 

Never reach under the furnace 
head with the hand or other parts 
of the body during operation,  
since there is a risk of crushing 
and a burn hazard.

2.1.13

 

Risks and dangers

 

This product contains ceramic  
fibres and may release fibre dust. 
Do not use compressed air, or 
blow, on the furnace thus  
distributing the dust in the  
environment and observe the 
additional notes on page 11.

  

2.1.14

 

Risks and dangers 

The furnace must not be operated if the quartz tube in the firing 
chamber is damaged. There is a risk of electric shock upon contact 
with the heating wire.

Содержание Programat CS

Страница 1: ...Operating Instructions Programat CS Valid as of Software Version 3 0...

Страница 2: ...2...

Страница 3: ...key functions 5 3 Basic meaning of the display information 5 4 Program structure 5 5 Adjustable parameters and possible value ranges 5 6 Settings test programs and information 5 7 Explanation of the...

Страница 4: ...20 Thermocouple cable 21 Vacuum hose connection 23 Rubber feet 24 Firing plate holder 25 Furnace head housing 26 Thermocouple plug 27 Plug fuse 28 Heater plug 29 Heater plug socket 30 Thermocouple pl...

Страница 5: ...5 40 25 34 6 10 35 23 47 33 1 7 5 2 3 24 4 8 9...

Страница 6: ...6 20 26 30 29 48 49 27 28 11 32 43 37 39 36 11 38 19 13 12 12 13 15 19 46 21 17 18 16 25...

Страница 7: ...right 80 Cursor key left 81 Information key 82 Program 1 83 Program 2 84 Program 3 85 Program 4 86 Next program 87 Open furnace head 88 Close furnace head 8 4 44 3 100 Programat firing tray 101 Metal...

Страница 8: ...ave the following meanings Risks and dangers Important information Contraindication Burn hazard Risk of crushing The Operating Instructions must be read 1 3 Notes regarding the Operating Instructions...

Страница 9: ...t be observed The instructions regulations and notes in the material s Instructions for Use must be observed The furnace must be operated under the indicated environmental and operating conditions Cha...

Страница 10: ...hazard Never place objects in the firing chamber by hand since there is a burn hazard Always use the tongs accessories supplied for this pur pose Never touch the hot surface of the furnace head as th...

Страница 11: ...original spare parts The temperature range for faultless operation is 5 C to 40 C 41 F to 104 F If the furnace has been stored at very low temperatures or high atmospheric humidity the head has to be...

Страница 12: ...ctronic controls and a software Moreover the set and actual temperatures are continuously compared 3 4 Accessories not part of the delivery form Automatic Temperature Checking Set 2 ATK 2 Programat Ac...

Страница 13: ...Simply use the two corresponding inserts Fold the side flaps 2 and combine the two packaging parts by means of the transportation flaps The packaging may be disposed with the regular household refuse...

Страница 14: ...5 on the firing plate holder 24 Secure the cooling tray 34 with the two screws 35 including the silicone washer 47 Place the cooling tray 34 on the frame plate 7 Make sure that the cooling tray 34 is...

Страница 15: ...nace head mounting Ensure that the furnace head mounting mark 41 is aligned with the furnace base mounting mark 42 Make sure that the firing plate 5 is not damaged by mounting the furnace head Step 4...

Страница 16: ...itional connections Power connection Please make sure that the voltage indicated on the rating plate complies with the local power supply Connect the power cord 16 with the power socket 17 of the furn...

Страница 17: ...with the wall socket 2 Put the On Off switch 11 at the rear of the furnace on position I The furnace will now automatically conduct a self test The performance of all furnace components is automatica...

Страница 18: ...rogram Starting a program is only possible with the furnace head open Start LED 74 Illuminated if a program has been started The LED is blinking while a program is paused STOP key 75 Pressing this key...

Страница 19: ...ration and information 5 5 Adjustable parameters and possible value ranges Symbol Parameter Value range Value range P Program number P 1 20 B Stand by temperature 100 700 C 212 1292 F S Closing time m...

Страница 20: ...by means of the or keys The tune can be set by means of the or keys Enables the pro gramming of the parameters of the currently selected program Settings Renaming Time Date General write protection V...

Страница 21: ...e Ivoclar Vivadent optimized temperature control function With this setting all values and para meters can be reset to the factory settings Attention All individual pro grams which have been created a...

Страница 22: ...fic program two stage program is used The bold line indicates the values for the second stage Furnace head Is shown in the recommendation open area and indicates the most likely action to follow Furna...

Страница 23: ...m Step 1 Select a free program Step 2 Select the parameter list via the setting Programming 7 20 and change the program parameters using the keys After that change back to the Stand by screen by press...

Страница 24: ...e program is used the parameters are displayed for the first and the second stage in a separate screen Switching between the two screens is carried out using the symbol Change program stage indication...

Страница 25: ...lug in connections for correct fit Var external connections weekly Check if the furnace head opens smoothly and without excessive noise Opening mechanism monthly Check if the thermocouple is straight...

Страница 26: ...mend keeping the furnace head closed especially if the temperature drops below 150 C 302 F 7 5 Dehumidification program The condensation of water in the insulation of the firing chamber and the vacuum...

Страница 27: ...o hot to start a firing program start of a firing program 17 System Furnace head cannot 27 The furnace head cannot be moved to the final position It might be blocked by an external mechanical be initi...

Страница 28: ...ales Service if one of the following error messages being displayed 25 29 32 43 44 45 46 47 48 54 56 103 107 700 701 703 704 705 706 707 800 1010 1011 1012 1013 1014 1015 1016 1024 1025 1026 1028 1202...

Страница 29: ...n and off again Has the vacuum already been released Is the program still running Wait until the pro gram is complete Switch furnace off and on again Vacuum pump does not start working Is the vacuum p...

Страница 30: ...120 V Diameter 6 3 x 32 mm 200 240 V Diameter 5 x 20 mm Dimensions of the closed furnace Depth 430 mm width 305 mm 410 mm with Cooling tray Height 320 mm Usable size of the firing chamber Diameter 80...

Страница 31: ...uld correspond to the Software version which is used on your furnace 10 2 Program structure Program Description 1 Crystallization glaze program for IPS e max CAD HT LT 2 Corrective firing for IPS e ma...

Страница 32: ...ga St Rosedale PO Box 303011 North Harbour Auckland 0751 New Zealand Tel 64 9 914 99 99 Fax 64 9 914 99 90 www ivoclarvivadent co nz Ivoclar Vivadent Polska Sp z o o Al Jana Pawla II 78 00 175 Warszaw...

Отзывы: