18
Step 5:
Hinging on the hood
Once all cables are properly connected to the furnace base, the hood
(16) can be hinged over the connections until it snaps into place.
Step 7:
Establishing additional connections
Power connection
Please make sure that the voltage indicated on the rating plate
complies with the local power supply. Subsequently, connect the
power cord (31) with the power socket of the furnace (30).
The furnace may only be used with the supplied power
cord!
Vacuum pump connection
Connect the vacuum pump plug (35) with the vacuum pump socket
(34).
We recommend using only a vacuum pump from Ivoclar Vivadent,
since these pumps are especially coordinated with the furnace.
If other pumps are used, please observe and do not exceed the
maximum power consumption.
Do not shorten the vacuum hose! The minimum length of
the vacuum hose is 1.6 m.
Step 6:
Mounting the connection cover
Mount the connection cover (37) and secure it with the fastening
screw (38). Make sure that the lateral catch springs snap into place
when mounting the connection cover.
The furnace may only be operated with the hood and the
connection cover mounted.
37
38
30
31
34
35
4. Installation and Initial Start-Up
Creating a LAN connection
In order to use the IoT function, you need a LAN connection to your
web-enabled local PC network. Use the LAN network cable included
in the delivery for this purpose. Connect one plug to the ethernet
port (15) and the other one to the router (RJ45).
Creating a wireless LAN (WLAN) connection
As an alternative to a LAN connection, a wireless LAN connection
can be set up. Please observe the instructions "Setting up a WLAN
connection" under "Settings" in the respective Instructions for Use.
The wireless LAN network needs to comply with the wireless LAN
standard (IEEE 802.11n, b, g in the frequency band 2.4 GHz).