4.5.3 Start screen and self-test
Immediately after switching on, the display briefly shows the start
screen. Subsequently, the furnace conducts an automatic self-test.
The performance of all furnace components is automatically checked.
The following information is displayed:
Information
Self-test
The automatic self-test is in progress. The furnace is checking the
function of the furnace components.
The self-test was successful. No malfunctions were found.
The self-test was not successful. Please note the error message on the
display.
Temperature calibration
Temperature calibration of the furnace is not required.
Some time has passed since the last calibration. Please conduct a
calibration procedure.
Power supply
The power supply voltage is in the acceptable range.
The power supply is outside the acceptable range.
Software version
The currently installed software version is displayed.
If the self-test has been successful, the furnace will automatically display the screen to select the desired operating mode
(firing / pressing).
If the program recognizes a malfunction during the test, a corresponding error
message with the corresponding rectification information appears on the display.
The acoustic signal and the error message can be acknowledged with the
corresponding buttons.
Press the
[Next]
button to confirm the self-test.
Before the first firing, the firing chamber should be dehumidified using the dehumidification program
(see Chapter 5.4.7 for details).
Please note that the furnace may require a certain acclimation time after having been set-up. Particularly if the
furnace was exposed to considerable temperature changes (water condensation).