6.17.9 Setting Logging of Sensor Peak values (Expert user)
There are 2 ways in which the measured peak measurement values of a Sensor Device can be
stored in the log file. By default, this will be saved using a fixed time interval. However, it is also
possible to choose to have these measured values stored on a Remote On
→
Off input change.
This choice is set via the “
Log Sensor Peaks on Remote I/O
” parameter.
If necessary, go to the main screen
(Home).
If necessary, log in as
(User level, Expert), see Section 6.9.
Press
(Info). The (Information) screen of the HMI will now open.
Browse using the
and
buttons to the page with parameter “
Log Sensor Peaks on
RemoteI/O
” (You can also use the large non-visible areas to browse).
Click
(EditMode) to change the parameter.
Press
(Edit) after the “
Log Sensor Peaks on Remote I/O
” parameter.
The following screen will be opened.
Select “
Off
” if the measured Sensor Peak values are to be saved every set time interval
(see also parameter “
Log file refresh time
”).
Select “
On
” if the measured Sensor Peak values must be stored with each Remote On/Off flank
change.
Note:
-
The Device parameter “
Data logging
” must be set to “
On
” to save the measured Sensor
Peak values in the log file.
The screen will now close.
Press
(Home) to return to the main screen and log in again as a Basic user (see Section 6.9).