ManagerIQEasy_UM_9752103002_GB_V3_1
49
Ethernet IP address
0.0.0.0
Display of the IP address assigned to the
Manager IQ Easy. The FTP server can be used
via this IP address to access the log files of the
Manager IQ Easy via the network.
Buzzer
Off
Touching the screen surfaces does not produce
an acoustic signal.
On
When touching a screen with which a next action
is started, a short sound signal is given.
Buzzer frequency
2000 Hz
The pitch of the audio signal.
Buzzer beep length
70 ms
The length of the audio signal.
Software version
Identification of the current software version of
the HMI.
Device serial number
0
Serial number on the Manager IQ Easy.
Check configuration
No
No check is made on the correctness of the active
configuration.
Yes
It is checked whether the current configuration of
the system matches the saved configuration. An
error is given in the event of deviations.
Invalid shutdown popup
time
Off
After the Manager IQ Easy has been shut down
incorrectly, a pop-up window with the text
“
Invalid
shutdown
” will appear after restarting. This
parameter determines the amount of time after
which the pop-up window is automatically closed.
Off = the screen will remain until the user pushes
it away.
5 min
After incorrectly closing and restarting the
Manager IQ Easy, the pop-up window with the
warning “
Invalid Shutdown
” will remain on the
screen for the indicated time. The user can also
push the screen away earlier by pressing “
OK
” to
push.
10 min
15 min
30 min
Rescan Ext.Box timer
30 s
Time interval that determines the number of
seconds after which a Backplane or Extension
IQ Easy is searched for. If this parameter is set to
“
0s
”, the only way to search for newly connected
Extension IQ Easy units is to use the Action
“
Scan
Ext. Boxes
”.
Popup on disconnected
BP
No
If communication with the Backplane is lost,
a pop-up screen will not be displayed.
Yes
If communication with the Backplane is lost,
a pop-up window with this warning will be
displayed.