Page 5-6 LCD Programming
Revised 10/14
ITW
Dynatec
D
SERIES
V6
DCL
ASU
Manuals
Setup Your System's Parameters
System Parameter Setup refers to the process of programming the controller to meet the specif
‐
ic temperature requirements of your production. Temperature setpoints for each temperature
zone must be programmed as well as a standby temperature and high/ low alarm tolerances.
Choices must be made for program selection and pump (or motor) conditions. If desired, tem
‐
perature zone offsets and/ or a temperature zone enable may be selected.
The following is a step
‐
by
‐
step procedure for setting up the DynaControl with your system's
parameters.
Temperature Zones
Selecting Temperature Zones
From the Overview Screen, turn the Input Wheel slowly to view each temperature zone. As the
wheel is turned, you will see the names of the individual temperature zones on the top line of
the display. Zone names may be re
‐
programmed to suit the user, but ITW Dynatec's typical D
Series zone names are: PREMELT (drop
‐
in grid), HOPPER, HOSE, HEAD and AUX.
To select a zone, simply stop turning the wheel when the desired zone's name appears (example
below: HEAD 2). To the right, displayed on the top line, is this zone's programmed setpoint (ex.
SET: 320
F) and the actual current temperature of the zone (ex. ACT: 319
F).
Below the zone's name is the bar
‐
graph with the selected zone highlighted. Below the bar
‐
graph
you can see that this zone is #2 of the system's applicators. At the far right of the display, you
can see that this zone is turned ON.
Head 2 zone is selected
Head 2's Setpoint
Head 2's Actual (current) Temperature
Bar
‐
Graph
of all
zones
Head 2 is
turned ON (I)
Head 2 is highlighted on the bar
‐
graph
Содержание DYNAMELT D15 Series
Страница 3: ......
Страница 4: ......
Страница 10: ...Page viii Revised 11 14 ITW Dynatec D15 D25 D45 V6 DCL ASU Manual 20 63 ...
Страница 22: ...Page 2 8 Description Revised 10 14 ITW Dynatec D15 D25 D45 V6 DCL ASU Manual 20 63 ...
Страница 76: ...Page 5 28 LCD Programming Revised 10 14 ITW Dynatec D SERIES V6 DCL ASU Manuals ...
Страница 148: ...Page 7 14 Troubleshooting Revised 10 14 ITW Dynatec D SERIES V6 DCL ASU Manuals ...
Страница 204: ...Page 10 28 Component Illustrations Revised 10 14 ITW Dynatec D15 D25 D45 V6 DCL ASU Manual 20 63 ...
Страница 208: ...Page 11 4 Schematics Revised 10 14 ITW Dynatec D SERIES V6 DCL ASU Manuals LEVEL CONTROL SCHEMATIC PN 802972 REV A ...