LCD Programming Page 5-9
Revised 10/14
Manual Mode Adjustments
In Manual Mode, press the Enter Knob to program the pump speed. Then turn the Input Wheel
to increase or decrease the pump speed. (If desired, you may adjust the RPM increments at the
“0.5 RPM Increments” parameter on the System Configuration Menu.)
Or press F5 to scroll through the pre
‐
set speed shortcuts. The presets are 0, 30 RPM, 60 RPM or
90 RPM. Press F5 again until desired pre
‐
set is selected. No entry confirmation is necessary.
Auto Mode Adjustments
The ASU's pump must be programmed with a minimum and maximum percent of full (maxim
‐
um) speed when Auto mode is used. The maximum speed is used as a scaling factor between
the input signal (for example, a PLC or an external 0
‐
10V input) and the percent of full speed
value of the pump.
The minimum speed is necessary to keep the pump turning in order to maintain a minimum
amount of adhesive pressure through the hose and applicator head.
For instance, if the input signal is 10VDC at 100 meters per minute and the pump percent of full
speed is 100% (maximum speed), but the system is putting out too much adhesive, adjusting
the MAX value to 50 will allow the pump to slow down and adhesive output will decrease by
50%.
To Adjust:
Press the F5 button once to open a minimum RPM input field. Turn the Input Wheel
to select desired minimum speed. Press the Enter Knob to confirm. Press F5 again to open the
maximum RPM field. Turn the Input Wheel to select desired maximum speed. Press the Enter
Knob to enter the value.
F1 = Stop All Pumps
Press the F1 button to stop all the pumps. The controller will memorize the previous setting.
Press F1 again and the pumps will re
‐
start accordingly.
Press the RETURN button to return to the Overview Screen.
However, to select Manual mode, press the Enter Knob before turning the wheel. Pressing the Enter
Knob here toggles between mode selection and RPM selection. Once you are in Manual mode and
you have highlighted the RPM selection, turn the Input Wheel to your desired RPM value.
AUTO Mode is selected for Pump #1,
speed is 45.0 RPM
Auto mode readout for
F5 programming
Содержание DYNAMELT D15 Series
Страница 3: ......
Страница 4: ......
Страница 10: ...Page viii Revised 11 14 ITW Dynatec D15 D25 D45 V6 DCL ASU Manual 20 63 ...
Страница 22: ...Page 2 8 Description Revised 10 14 ITW Dynatec D15 D25 D45 V6 DCL ASU Manual 20 63 ...
Страница 76: ...Page 5 28 LCD Programming Revised 10 14 ITW Dynatec D SERIES V6 DCL ASU Manuals ...
Страница 148: ...Page 7 14 Troubleshooting Revised 10 14 ITW Dynatec D SERIES V6 DCL ASU Manuals ...
Страница 204: ...Page 10 28 Component Illustrations Revised 10 14 ITW Dynatec D15 D25 D45 V6 DCL ASU Manual 20 63 ...
Страница 208: ...Page 11 4 Schematics Revised 10 14 ITW Dynatec D SERIES V6 DCL ASU Manuals LEVEL CONTROL SCHEMATIC PN 802972 REV A ...