Page 10
ITW Dynatec
Rev.10.15
Appendix Pumps
Transport / Storage
DANGER
•
Death or crushing of limbs caused by falling or overturning loads!
•
Bodily harm can occur if excessive weight is lifted or moved incorrectly!
•
Protection from hot surfaces and hot liquids must be provided by the operator!
Take care not to drop the pump. Read and consider the weight prior to attempting to lift or
move the pump. Do not attempt to lift pumps heavier than 25 kg without the use of a
crane or other type of lifting assist device. Only qualified personnel may transport pumps
weighing more than 25 kg.
When working with pumps that are hot, wear proper protective equipment and note that
hot fluid may flow from the pump. Guard against skin contact with hot fluids, or with a hot
pump. Follow all precautions of the fluid manufacturer in the handling of the fluid.
In the event that a pump needs to be stored, always protect the pump against water and
other contaminants. Store the pump in a clean, dry, and warm environment. Pumps are
delivered filled with suitable lubricant and with protective covers in, or over, all openings.
These covers should remain in place during the mounting and alignment procedures, as
long as possible. Remove the covers just prior to attaching system hoses to the manifold.
While storing spare parts, always protect the parts from water and contaminants. Store
the parts in a clean, dry, and warm environment. Spare parts should be lightly coated with
rust preventative oil and sealed in an air tight container.
Содержание DYNAMELT D15 Series
Страница 3: ......
Страница 4: ......
Страница 10: ...Page viii Revised 11 14 ITW Dynatec D15 D25 D45 V6 DCL ASU Manual 20 63 ...
Страница 22: ...Page 2 8 Description Revised 10 14 ITW Dynatec D15 D25 D45 V6 DCL ASU Manual 20 63 ...
Страница 76: ...Page 5 28 LCD Programming Revised 10 14 ITW Dynatec D SERIES V6 DCL ASU Manuals ...
Страница 148: ...Page 7 14 Troubleshooting Revised 10 14 ITW Dynatec D SERIES V6 DCL ASU Manuals ...
Страница 204: ...Page 10 28 Component Illustrations Revised 10 14 ITW Dynatec D15 D25 D45 V6 DCL ASU Manual 20 63 ...
Страница 208: ...Page 11 4 Schematics Revised 10 14 ITW Dynatec D SERIES V6 DCL ASU Manuals LEVEL CONTROL SCHEMATIC PN 802972 REV A ...