Page 7-34 Troubleshooting
Revised 10/14
ITW
Dynatec
D
SERIES
V6
DCL
ASU
Manuals
Solution
1. Remove seal and bearing from pump.
Verify that all components are
correctly positioned.
2. Remove seal from pump, inspect it
and replace it if worn or damaged.
Be sure there are no burrs or other
sharp edges on pump shaft or on
installation tools that could damage
a new seal.
1.Remove seal from pump, inspect it
and replace it if worn or damaged. Be
sure there are no burrs or other sharp
edges on the rear plate o-ring groove
that could damage a new o-ring.
2. Verify that all four pump retaining
nuts are tightly assembled to the
studs.
3. Remove pump and inspect hopper.
Repair or replace hopper as necessary.
Problem
Possible Cause
Adhesive leak at pump
1. Pump seal is incorrectly
shaft seal.
positioned inside the seal
and bearing assembly.
2. Pump seal inoperative.
Adhesive leak at pump- 1. O-ring in pump’s rear
to-hopper interface.
plate is inoperative.
2. Pump retaining nuts are
missing or loose.
3. Helicoil insert pulled out
of hopper.
Seal assembly
Pump
Rear Plate
O-ring
Содержание DYNAMELT D15 Series
Страница 3: ......
Страница 4: ......
Страница 10: ...Page viii Revised 11 14 ITW Dynatec D15 D25 D45 V6 DCL ASU Manual 20 63 ...
Страница 22: ...Page 2 8 Description Revised 10 14 ITW Dynatec D15 D25 D45 V6 DCL ASU Manual 20 63 ...
Страница 76: ...Page 5 28 LCD Programming Revised 10 14 ITW Dynatec D SERIES V6 DCL ASU Manuals ...
Страница 148: ...Page 7 14 Troubleshooting Revised 10 14 ITW Dynatec D SERIES V6 DCL ASU Manuals ...
Страница 204: ...Page 10 28 Component Illustrations Revised 10 14 ITW Dynatec D15 D25 D45 V6 DCL ASU Manual 20 63 ...
Страница 208: ...Page 11 4 Schematics Revised 10 14 ITW Dynatec D SERIES V6 DCL ASU Manuals LEVEL CONTROL SCHEMATIC PN 802972 REV A ...