REPLACING WORN-OUT PARTS
Disassembling pump-motor coupling box
(Tab 5)
Take off the pump casing by unscrewing assembling
nuts (part.4) and lever between pump and coupling
box.
The following points are important in connection
with work on the pump
.
The pump is designed for use with liquids which
can be a health risk. In order to prevent injury to the
eyes and skin, observe the following points when
working on the pump:
WARNING!
Make sure that the pump has been
thoroughly cleaned;
Beware of the risk of infection;
WARNING!
Observe local safety regulations.
Always wear goggles and rubber gloves
Rinse the pump thoroughly with water before starting
work.
Rinse the components in water after dismantling.
10
5
WARNING!
The oil chamber may be under pressure.
Hold a rag over the filling plug to prevent splatter.
WARNING!
Proceed as follows if fluid have splashed
into your eyes:
- Rinse your eyes immediately in running water for
15 minutes. Hold your eyelids a part with your
fingers.
- Contact an eye specialist.
on your skin:
- Remove contaminated clothes
- Wash your skin with soap and water
- Seek medical attention, if required
Coperchio acqua