21
3.2.2. Mounting positions
ä Attention
!
Attach the ventilation unit to a concrete surface, not to a wooden
or plaster surface or to a surface with insufficient load-bearing
capacity
(˂
200 kg/m2). This leads to noise nuisance.
The ventilation unit can be mounted directly on the floor or on the
wall with the supplied wall bracket set. A pot set (optional) is also
available.
The pictograms on the top of the appliance, near the duct
connections, indicate where the ducts of the house are to be
connected.
You must always connect a minimum of 4 channels. You can use
connections A and B and at least C or E and at least D or F.
ä Attention
!
Always ensure that the ventilation unit is mounted in such a way
that the ducts are connected to the correct inlet and outlet
openings!
ä Attention
!
The appliance must be mounted vertically and level!
Mounting
position
B
B
A
C
A
D
E
F
Legend
A
Exhaust air to the outside
B
Supply air from outside
C-E
Supply air to home
D-F
Exhaust air from home
Содержание HRU 400