Technical data
Page 44
Table 15:
Controller C 1-02: Rated current for an ambient temperature of
≤
40 °C
Parameter
Values
Power stage clock frequency (kHz)
≤
12
Output current (A
RMS
)
2,5
Max. output current (A
RMS
)
5
7,5
10
Max. allowed time (s)
5
1,3
0,5
Power stage clock frequency (kHz)
16
Output current (A
RMS
)
2,2
Max. output current (A
RMS
)
4,4
6,6
8,8
Max. allowed time (s)
5
1,3
0,5
Power stage clock frequency (kHz)
19
Output current (A
RMS
)
1,9
Max. output current (A
RMS
)
3,8
5,7
7,6
Max. allowed time (s)
5
1,3
0,5
Table 16:
Controller C 1-05: Rated current for an ambient temperature of
≤
40 °C
Parameter
Values
Power stage clock frequency (kHz)
≤
12
Output current (A
RMS
)
5
Max. output current (A
RMS
)
10
15
20
Max. allowed time (s)
5
1,3
0,5
Power stage clock frequency (kHz)
16
Output current (A
RMS
)
4,4
Max. output current (A
RMS
)
8,8
13,2
17,6
Max. allowed time (s)
5
1,3
0,5
Power stage clock frequency (kHz)
19
Output current (A
RMS
)
3,7
Max. output current (A
RMS
)
7,4
11,1
14,8
Max. allowed time (s)
5
1,3
0,5