Technology modules
Page 154
12.3
General installation notes for technology modules
DANGER!
Non-observance of the instructions that are stated in
Safety notes for electrical drives and
page 16
) may lead to property damage, injuries, electric shock, or – in extreme cases – even
death.
DANGER!
Prior to installing technology modules, the servo positioning controller has to be disconnected from any
current-carrying conductors. After the operating voltage has been disconnected, wait for 5 minutes so that the
capacities in the servo positioning controller can be completely discharged.
Caution!
Make sure that ESD protection measures are taken when handling technology modules.
To insert a technology module into the item servo positioning controller C 1-Series, please proceed as follows:
Remove the front plate of the technology slot (TECH 1 or TECH 2) of the servo positioning controller with a suitable Phillips
screwdriver.
Push the technology module into the open technology slot so that the lateral guides hold the board.
Push the technology module into the slot until it reaches the stop.
Screw the technology module onto the front side of the housing of the servo positioning controller with the Phillips screw.
Ensure that the front plate of the technology module has conducting contact with the housing of the servo positioning
controller (PE).
Figure 30:
Servo positioning controller with integrated technology module