6.- START UP AND REGULATION
STAND
: Check that the pump is properly installed in its stand.
OIL
: Take off re-filling lid and fill the pump with the provided oil: SAE
80 W 90 or equivalent. If the pump has several modules oil must be
spread to all filling holes.
Lubricants list:
CEPSA SAE 80W 90
REPSOL EP 80W/90
SHELL SPIRLAX HD OIL 80W/90
ESSO GEAR OIL 80W/90
AGIP ROTRA MP 80W-90
MOBILUDE HD 80W-90
BP ENERGEAR HT 80W-90
CASTROL HYPOYC
GULF GEAR MP SAE 80W 90
ELF TRANSGEAR HD 80W-90
Check the oil level with the provided dipstick.
Aproximate oil capacity: 100 cm3 per module.
When carrying change filling lid for working lid.
CHECKING OF HYDRAULIC CIRCUIT
: Check that all valves are
opened and that escapes from priming valves derive the liquid to a
proper receptacle.
ROTARY DIRECTION
: Start up the pump to check that the rotary
direction coincides with the one shown by the arrow. To change rotary
direction invert two phases in the motor terminals box.
CHECKING OF PUMP
: Check visually/auditorilly the proper working
of the pump.