7.- MAINTENANCE
Before any maintenance operation we will check:
That the pump is stopped and disconnected from the electric
supply.
There is no pressure neither inside the head nor in the impulsion
pipe. It is advisable to empty the head before opening it.
The staff in charge of the maintenance will use the adequate
protection means in order to manipulate the dosed liquid.
PERIODICAL MAINTENANCE:
Change oil after the first 500 hours. Next changes will be every 2000 hours
(minimum once a year).
Check the piston every 3 months or 1000 hours.
Check the bellows every 3 months or 1000 hours.
Check the suction filter once a month.
Check the valves every 3 months or 1000 hours.
It is advisable to clean periodically the injector, letting clean water flow through it
(We can make it coincide with the emptying out of the tank), to eliminate
precipitated rests that can remain in the inner part of the cylinder or in suction /
impulsion pipes.
If we are using higly corrosive liquids it is advisable to double the
frequency of checkings.