10
To evacuate leaks by the hole of the diaphragm breakage detector
in the inferior part of the cylinder (R ½”), we will take off the security
bolt disassembling the cylinder and connceting a hose or a pipe of
a material compatible with the product to be dosed, and collect the
liquid in a safe place.
ON
OFF
OVERLOADED SWITCH
L
N
N
L
115 VAC (60 Hz)
230 VAC (60 Hz)
7.6 Amp.
3.8 Amp.
230 VAC (50 Hz)
WIRE
INCLUDED
3.1 Amp.
HYDRAULIC CONNECTION
SINGLE-PHASE CONNECTION
To work at 230 V single-phase at 50 Hz we will connect directly the motor wire to
the adequate protection. To work at 60 Hz we will connect the connection box
plates as shown in the drawing.
ON
OFF
OFF
OVERLOADED SWITCH
U
V
W
400 V
V1
W1
U1
1.5 Amp
THREE-PHASE CONNECTION (50/60 Hz)
To work at 230 V we will plug the motor in triangle.
To work at 400 V it will be a star connection.
V1
W1
U1
230 V
2.6 Amp