Recommended Target Debug Connectors and Position
The target debug connector is a 10-pin, 1.27mm, double-row connector (e.g. Samtec FTSH-
105-01-L-DV,Samtec FTSH-105-01-L-DV-K with Keying Shroud).
1. Use the target debug connector(s) with
the
Keying Shroud
option since incorrect connection
can cause damage to the hardware.
2.
Pin 1 of the connector(s) should be located toward the PCB’s edge to prevent the need to
twist or fold the debug ribbon cable(s) (see the picture below).
3. When using DAP and the DAPE debug interfaces, the
DAPE connector
should be placed to
the left of the
DAP connector
when looking from the edge of the PCB. The connectors must be
at least 11.0 mm apart, although a distance of 16.8 mm is recommended. The goal should be
to link the Active Probe to the target hardware via non-twisted and, when DAPE is used, parallel
ribbon cables.
IA10PIN10P-AP-CUST custom length DAP interface ribbon cable
Optionally, a longer ribbon cable can be ordered under the ordering code IA10PIN10P-AP-
CUST. The length must be specified at the order.
iSYSTEM gives no assurance for BlueBox operation with this cable. The cable is meant
to be used only for boundary cases where BlueBox can't be connected to the target
hardware through the standard debug adapter, e.g. due to the physical obstacles of the
target system. In such cases, operating the BlueBox at lower debug frequency scan
speeds and not using the trace functionality at all, might be still an acceptable
compromise. It’s up to the user to thoroughly test and qualify the BlueBox operation
using custom length ribbon cable and to determine working winIDEA settings for the
system.
Содержание IC57163
Страница 1: ...Infineon DAP DAPE Active Probe User Manual V2 7 ...
Страница 8: ...Operation Device overview ...
Страница 16: ...4 optional In case of DAPE connector repeat step 2 and 3 with the second cable ...
Страница 22: ...User Notes This page is intentionally left blank ...
Страница 23: ...This page is intentionally left blank ...