57
If the fire extinguishing system comes into an active state for any reason other
than fire and the tanks are empty, the following procedures must becarried out:
1. Wash all component surfaces affected by the system with water to avoid
corrosion of the parts in the engine chamber.
2. Supply water to the fire extinguishing tubing system and wash inside of the pipes
and nozzles. If it is late for this process, remove the nozzles and pipesin order to
clean. Change the nozzles if necessary.
3. Put on protective covers on the nozzles again.
4. Mount the filled tanks and reengage the system.
For fire extinguishing system, the extinguishing fluid should be replacedevery 5
years and the tanks should be replaced every 10 years.
ENGINE CHAMBER FIRE DETECTION SYSTEM AND CONTROL UNIT
Fire detection system gives a red light
and buzzer on the warning lens panel when
a temperature value above 120
°
C in engine chamber is detected.
The control module provides audible and visual warning to detect the fire and activate the
extinguishing tube simultaneously with the signal sent by the linear temperature sensor
cable that detects the heat.
Содержание NOVOULTRA E6 2019
Страница 1: ...USER S MANUAL Revision No 01...
Страница 5: ...1 INTRODUCTION 1...
Страница 11: ...7 2 GENERAL INFORMATION...
Страница 14: ...10 3 CONTROLS AND INDICATORS...
Страница 33: ...29 ASR failure Error...
Страница 34: ...30 4 VEHICLE EQUIPMENT...
Страница 64: ...60 5 SERVICE AND MAINTENANCE...
Страница 97: ...93 6 TECHNICAL INFORMATION...
Страница 101: ...7 LIST OF FOREIGN DISTRIBUTORS 96...