55
ENGINE CHAMBER FIRE DETECTION SYSTEM
Fire detection system gives a red light
and buzzer on the warning lens panel when
a temperature value above 120
°
C in engine chamber is detected.
ENGINE CHAMBER FIRE EXTINGUISHING SYSTEM (OPTIONAL)
Fire extinguishing system consists of temperature sensors and water-spray nozzles in
the engine chamber where fire is likely to occur. The water is atomized at 200 bar
pressure and the nozzles discharge the water mist. The increased surface area of the
water droplets produces an immediate cooling effect and displaces oxygen in the
engine compartment, smothering the fire.
1. FIRE button
Press the fire button to activate
immediately the suppression system
manually.
2. ACTION button
2.1. Normal operation mode:
•
Short
press
has
no
functionality.
•
Long press will start the LED &
Alarm self-test.
2.2. Warning/diagnosis mode:
•
Short press:
o
First
press
will
silence/mute the warning
signal.
o
Every further press will
show you the “Fault
Display”. If there is at least
one error.
•
Long press will reset the
warnings.