53
Earthcore Industries
01/2020
Isokern Maximus Linear Series Gas Fireplace
Remote Control System
OFF
SMART
MAX
Flame Level 5
Transmission
Thermostat
Off/Smart
Set Point
Temp./Level/State
Flame On
Child Safety Lock-Out
Low Battery Alarm
Room Temperature
Maximum Level Indicators
Flame Level Maximum
OFF
OFF
OFF
SMART
MAX
Flame Level 5
Transmission
Thermostat
Off/Smart
Set Point
Temp./Level/State
Flame On
Child Safety Lock-Out
Low Battery Alarm
Room Temperature
Maximum Level Indicators
Flame Level Maximum
OFF
OFF
No Blue Flame
Center
Soot at
Flame Tip
Dark Orange
Flame
IMPROPERLY
BURNING FLAME
Soot above
Flame Tip
No Soot at
Flame Tip
PROPERLY
BURNING FLAME
Semi-Transparent
Yellow Flame
Blue Flame
Center
Ports on Pan
Burner Assembly
Burner Flame Appearance
FIGURE 33
FIGURE 34
FIGURE 35
ON/OFF Key
THERMOSTAT Key
UP/DOWN Arrow Key
MODE Key
Blue LCD Display
FIGURE 32
Temperature Indicator Display
With the system in the “OFF” position, press the Thermostat Key and the Mode
Key at the same time.
(Figure 56)
Look at the LCD screen on the Remote to verify
that a C or F is visible to the right of the Room Temperature display.
(Figure 57)
Turn On The Appliance
Press the ON/OFF Key on the Remote. The Remote display will show all active
Icons on the screen and the appliance main burner will turn on.
(Figure 33)
A single
“beep” from the Receiver will confirm reception of the command.
Turn Off The Appliance
Press the ON/OFF Key on the Remote. The Remote LCD display will only show
the room temperature and Icon and the appliance burner will turn off. A single “beep”
from the Receiver confirms reception of the command.
Remote Flame Control
The system has six (6) flame levels. See
Figure 33
for an example. With the
system on, and the flame level at the maximum in the appliance, pressing the Down
Arrow Key once will reduce the flame height by one step until the flame is turned off.
The Up Arrow Key will increase the flame height each time it is pressed. If the
Up Arrow Key is pressed while the system is on but the flame is off, the flame will
come on in the high position.
(Figure 34)
A single “beep” will confirm reception of
the command.
Flame Color and Behavior
This appliance is designed for maximum heating efficiency. Therefore, upon
lighting of the main burner, the flames will be semi-transparent or “bluish.” After 10-
20 minutes of operation the logs will heat up and the flames will become a yellow/
orange color.
Adjusting the appliance to cause the flames to turn orange sooner may result in
poor combustion, sooting and a hazardous situation. See
Figure 35
showing proper
flame appearance.
When testing for proper operation - If an optional thermostat is installed adjust it
to its highest temperature setting. Visually determine that main burner gas is burning
properly: i.e., no floating, lifting or flashback. Adjust the primary air shutter(s) as
required. Check for proper main burner operation at both high and low flame.