Earthcore Industries
Isokern Maximus Linear Series Gas Fireplace
01/2020
Burner Installation
Prior to installation: Shut off main gas supply to fireplace.
The ISOFLAMES Linear Burner system shall be installed by qualified professional service technician. To ensure proper
performance of the appliance the owner’s installation manual must be followed carefully.
When used in the Maximus Linear Fireplace, the ISOFLAMES Linear Burner is designed to be recessed into the 2 1/2” deep
firebrick cavity constructed as detailed in the Firebrick Installation portion of this manual
(Figure 28 and 29)
The burner cavity must have a height of 21/2”, a minimum depth of 83/4” and the length shall correspond to Table 5.
If the gas supply pipe, from the externally mounted valve, is brought into the cavity through the sidewall of the firebox, the
cavity must extend completely to the firebox sidewall.
For models ISF24/36/48LB: Gas supply piping shall terminate not less than 3” from sidewall.
For models ISF72/96LB Gas supply stub piping shall terminate within 3” from center of the cavity.
(Figure 38 & 39)
BURNER CAVITY DIMENSIONS (in)
Burner Model
Height
Width
Length
ISF24LB 2
1/2 8
3/4 23
ISF36LB 2
1/2 8
3/4 35
ISF60LB 2
1/2 8
3/4 59
ISF72LB 2
1/2 8
3/4 71
ISF96LB 2
1/2
8 3/4
95
TABLE 5
FIGURE 38
FIGURE 39
See Table 5
≈9"
≈5"
≈6"
VOID