background image

12

Earthcore Industries

Isokern Maximus Linear Series Gas Fireplace 

01/2020

16-5/8”

124-1/8”

5”

2¾”

Front View

Side View

Plan View

Top View

10¾”

Uses one 12” B-Vent Chimney with mechanical exhaust 
fan. Refer to product manual for approved Metal Chimney 
manufacturers.

132”

62-7/8”

18-7/8”

15-3/8”

8”

20-5/8”

62-7/8”

25-1/4”

116-11/16”

28”

122”

122”

29-7/8”

20-5/8”

12-3/8”

15-3/8”

18-7/8”

132”

127-1/8”

Steel angle:  
6” x 6” x 1/2” cut to span 
firebox opening. This item 
is not included in the com-
ponents and can be sourced 
locally.

Isokern Maximus Linear Series - Glass Front Kit 120” (GFK-120)

You will need to order the 82L120 and GFK-120 to build the complete Glass Front Fireplace

Component 

Part#  

Description

E-ACB-C

Isokern LINEAR

Collector Box Assembly C (Qty:2)

M90B

Isokern LINEAR 

Sidewall (Qty. 2)

Component 

Part#  

Description

Isokern LINEAR 

Baseplate

22

Isokern LINEAR

Ceramic Glass (Qty: 3)

42

15

16

9

7

16

9-7/16”

17-1/2”

Isokern LINEAR

Top Glass Bracket (Qty: 4)

E-TG2

16-5/8”

34-3/16”

25 ¼”

48”

9½”

73

Isokern LINEAR 

Backwall

34½”

Isokern LINEAR 

Baseplate

Isokern LINEAR 

Baseplate

23

125

28”

28”

53”

30½”

66”

Isokern LINEAR  

Back wall

71

162

Isokern LINEAR  

Back wall

(162) BACKWALL; MIDDLE (7',8',10' )

QTY: 10

1

2

"

31 

1

8

"

9½”

(160) BACKWALL (7', 8' )

QTY: 5

1

2

"

29 

5

8

"

9½”

38½”

31-1/8”

25-1/4”

CG4

16-5/8”

57-3/4”

25 ¼”

25 ¼”

Содержание 82L120

Страница 1: ...re to follow safety warning exactly could result in serious injury death or property damage Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appl...

Страница 2: ...lass Media Options 55 Optional Log Sets 56 Warranty Card 57 Warranty Disclaimer 58 ISOKERN LINEAR GAS FIREPLACE LISTED VENTED GAS FIREPLACE PER ANSI Z21 50 2019 CSA 2 22 2019 NOT FOR USE WITH SOLID FU...

Страница 3: ...ything solid fuel other than the listed gas log unit and the type of gas approved for use in this gas appliance The most important areas of concern with the installation of the top venting Isokern Max...

Страница 4: ...building codes governing fireplaces and fireplace installations The Isokern Maximus Linear Series installation must comply with all local regional state and national codes and regulations 2 The Isoker...

Страница 5: ...or any other product not specified by the manufacturer herein for use with this fireplace 22 Do not use any Isokern Maximus Linear Series appliance if any part has been under water Immediately call a...

Страница 6: ...M67 Isokern LINEAR Backwall Component Part Description Isokern LINEAR Baseplate 23 CG1 Isokern LINEAR Ceramic Glass 523 4 9 7 16 52 3 4 9 7 16 17 1 2 40 9 1 2 15 45 3 16 5 2 Front View Side View Plan...

Страница 7: ...eplace Component Part Description 28 53 M93 Isokern LINEAR Base Plate 3 25 16 34 Isokern LINEAR Side Sloping Qty 2 28 8 9 2 M90 Isokern LINEAR Sidewall Qty 4 M94L M94R Isokern LINEAR Damper End Left R...

Страница 8: ...ramic Glass Qty 3 4215 16 9 7 16 42 15 16 9 7 16 17 1 2 Isokern LINEAR Top Glass Bracket Qty 3 E TG2 16 5 8 78 1 4 5 2 Front View Side View Plan View Top View 10 Uses one 12 B Vent Chimney with mechan...

Страница 9: ...Smoke Dome Qty 2 4 16 36 18 Isokern LINEAR Smoke Dome Qty 2 4 16 3 25 16 34 Isokern LINEAR Side Sloping Qty 2 28 8 9 2 M90 Isokern LINEAR Sidewall Qty 4 9 73 Isokern LINEAR Backwall Qty 2 Component P...

Страница 10: ...x 1 2 cut to span firebox opening This item is not included in the components and can be sourced locally Component Part Description E ACB A E ACB C Isokern LINEAR Collector Box Assembly A Collector B...

Страница 11: ...122 Isokern LINEAR Top Plate Left Right Qty 2 M94L M94R Isokern LINEAR Damper End Left Right Isokern LINEAR Back wall Qty 25 160 Isokern LINEAR Base Plate 191 162 Isokern LINEAR Back wall Qty 2 73 Iso...

Страница 12: ...ss Front Kit 120 GFK 120 You will need to order the 82L120 and GFK 120 to build the complete Glass Front Fireplace Component Part Description E ACB C Isokern LINEAR Collector Box Assembly C Qty 2 M90B...

Страница 13: ...M94L M94R Isokern LINEAR Damper End Left Right Isokern LINEAR Back wall Qty 4 162 71 Isokern LINEAR Back wall Qty 2 73 Isokern LINEAR Back wall Qty 2 116 Isokern LINEAR Smoke Dome Qty 2 116 SMOKE DOME...

Страница 14: ...article board mill board plywood paneling plywood sub flooring and wood flooring CAUTION Maintain three inches 3 clearance to insulation and vapor barriers from all firebox smoke dome and B Vent flue...

Страница 15: ...cludes steel angle but no burner flue accessories c LINEAR 96 3 132 lbs includes steel angle but no burner flue accessories d LINEAR 120 3 844 lbs includes steel angle but no burner flue accessories 2...

Страница 16: ...raised hearth detail 3 Rough framing dimension for depth C allows for the required 1 1 2 clearance at the back of the fireplace 29 1 2 is only for an interior wall as most exterior wall framings have...

Страница 17: ...he face of the entire joint as a sign of complete and proper sealing of the joint On broader contact surfaces it is advisable to apply several additional 1 2 beads of the Earthcore Adhesive to the are...

Страница 18: ...supporting floor system Do not set the base plate so that it is in span Refer to pages 25 28 for part dimensions 2 Set the first course of the firebox side walls and back walls into place Figure 9 NO...

Страница 19: ...e Isokern unit Figure 10 Maximus Linear Glass Front Kit Installation Collector Box 48 Part Assembly B 72 Part Assembly A A 96 Part Assembly A C 120 Part Assembly C C FIGURE 10 4 Then you will place th...

Страница 20: ...e unit between the lowest wall component and the top surface of the base plate Any gap created under the wall components during the shim leveling process must be filled with Earthcore Adhesive to fill...

Страница 21: ...of the firebox side wall so that its interior bottom edge aligns with the interior angle of the firebox side wall that it sits on Figure 13 The lintels will be equal to the width of the fireplace mode...

Страница 22: ...Model will come with one glass bracket that will be secured to the underside of the front damper beam using the tap con screws provided Figure 15 GLASS BRACKET SEE DETAIL 70 M94R M94L 70 ALIGNMENT TAB...

Страница 23: ...haunches at the ends of the front and rear smoke dome components Apply Earthcore Adhesive to all contact surfaces thoroughly The smoke dome sloping side walls have a beveled bottom edge so that they w...

Страница 24: ...M91 21 21 72 73 72 73 72 73 M94R M90 M90 M90B M90 M90 M90B 69 69 83 18 16 121 121 77A 34 Assembled LINEAR 96 Glass Front 23 21 162 160 M94R M90 M90 M90B M90 M90 M90B 68 68 16 17 122 122 77A 34 113 68...

Страница 25: ...to exceed twenty feet 20 of four inch 4 pipe If you require a longer length we recommend that you use a six inch 6 diameter pipe for the complete run of up to forty feet 40 WARNING Do not use combust...

Страница 26: ...as occupied spaces or anywhere the surface of the chimney could be contacted by persons or combustible materials The air space between the outer wall of the chimney and the enclosure shall not be less...

Страница 27: ...t 18 Length 12M4 B Vent 4 Length 12M5 B Vent 5 Length 12M12A B Vent 12 Adjustable Length 12M18A B Vent 18 Adjustable Length 12M45 45 Deg Adjustable Elbow 12MDD 12 B Vent Draft Diverter B Vent Metal Ch...

Страница 28: ...raft Diverter in a location inaccessible for inspection cleaning and servicing after installation 2 Starting at the anchor plate attach the first section of B Vent Pipe It is acceptable to use screws...

Страница 29: ...on vent sections exposed to atmosphere At the roof the opening should be 2 inches 51 mm greater than the B Vent OD Above the roof a flashing is required to maintain the one inch 25 4 mm clearance to t...

Страница 30: ...nent s individual manuals TO REDUCETHE RISK OF FIRE ELECTRICAL SHOCK OR INJURYTO PERSONS OBSERVETHE FOLLOWING 1 Use this unit in the manner intended by the manufacturer If you have questions contact t...

Страница 31: ...the gas valve for fireplace operation The actuator has two end switches to prove damper position open or closed and is equipped with the Enerdrive fail safe system to open the damper in the event of...

Страница 32: ...quired by the authority having jurisdiction the installation must also conform to the Standard for Draft Equipment and The National Fuel Gas Code ANSI Z223 1 NFPA 54 All electrical wiring must be in a...

Страница 33: ...one mounting hole in each corner of the adapter Use bolts and locking nuts to secure the fan to the MFD WIRING OF A GAS FIREPLACE WITH A DAMPER 6 The MFD must be interlocked to an ENERVEX control When...

Страница 34: ...TION COMPONENT LIST PART ID PART DESCRIPTION 1 SC121204M MODIFIED 12X12X4 GAS VALVE ENCLOSURE 2 PSE C7 531 84 PILOT ASSEMBLY 3 SIT0 855 006 SIT PROFLAME2 855 MODULATING VALVE NAT 4 SIT0 584 308 SIT PR...

Страница 35: ...lied Approximately 35 to 40 lbs of prepared mortar will lay up one hundred 9 x 4 x 2 straights DO NOT add additives such as fire clay sand cement or other accelerators These instructions may vary beca...

Страница 36: ...4 Starting approximately 1 2 from the front edge of the unit s sidewall apply split firebrick to the side wall of the unit Ensure approximately 1 4 gap is kept between firebrick and damper beam assem...

Страница 37: ...e noncombustible finish material and the rough front face of the Isokern Smoke Dome Figure 31 Be sure to fill this gap with Earthcore Adhesive in conjunction with placement of the code required noncom...

Страница 38: ...e Maximus Linear with Glass Front has been tested to zero clearance to combustible mantel and sheathing Prior to installation verify that additional clearances are not required by local code Figures 3...

Страница 39: ...must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psi 3 5 kPa The appliance must be isolated from the gas piping sys...

Страница 40: ...revious code editions in local jurisdictions or in specific situations may differ 25 Never install an ISOFLAMES Linear Burner component or accessory that has visible or suspected physical damage as a...

Страница 41: ...influence of alcohol Earthcore Industries strongly recommends the use of a carbon monoxide detector alarm device wherever gas fired appliances are in use All parties either involved in or associated w...

Страница 42: ...24 36 48 60 72 96P 1 2 1 1 3 1 ISF E PAN ISF E PAP ISF E GVN ISF E GVP 1 4 1 5 1 6 ISF E CM ISF E BH ISF E RM 1 7 1 8 1 9 Main Burner Assembly natural gas Main Burner Assembly propane Pilot Assembly...

Страница 43: ...place Masonry Built Fireplace Chimney height ft Minimum Venting Requirements Note Height is measured from hearth to top of chimney and the minimum height is 10 ft Note Height is measured from hearth f...

Страница 44: ...causing a hazardous condition 6 Make sure piping is clean and free from burrs Apply a small amount of good quality pipe thread compound or plumbers tape suitable for the gas being used Thread compound...

Страница 45: ...For a copy of the home owner s care and operation manual go to www earthcore co or call 1 800 642 2920 Main Gas Inlet 3 8 NPT Inlet IN Test Port Hi Lo Flame Control Knob Yellow Ground Wire from DFC w...

Страница 46: ...tion of this manual Figure 28 and 29 The burner cavity must have a height of 21 2 a minimum depth of 83 4 and the length shall correspond to Table 5 If the gas supply pipe from the externally mounted...

Страница 47: ...female adapter Avoid creating kinks in the flex connector 8 Make sure all connections are tightly secured 9 Place the removed burner top back on to the orifice block and secure tightly with the pan he...

Страница 48: ...ries 01 2020 Isokern Maximus Linear Series Gas Fireplace 36 Burner Connection ISF36LB For Isokern Maximus Linear 82L48 Box No Part No Qty 4 E 18BP4 1 8 E 12BP1 1 ISF36LB 60 Burner Connection ISF60LB F...

Страница 49: ...Industries 01 2020 Isokern Maximus Linear Series Gas Fireplace 72 Burner Connection ISF72LB For Isokern Maximus Linear 82L96 Box No Part No Qty 4 E 18BP4 1 5 E 18BP5 1 9 E 12BP2 1 10 1 13 E 12BP3 E B...

Страница 50: ...rn Maximus Linear Series Gas Fireplace 01 2020 96 Burner Connection ISF96LB For Isokern Maximus Linear 82L120 11 11 Box No Part No Qty 2 E 18BP2 1 3 E 18BP3 1 9 E 12BP2 1 10 E 12BP3 1 11 E 12BP4 1 12...

Страница 51: ...ck these items before the initial lighting of the appliance o Gas pressure has been checked carefully o All gas fittings have been checked for leaks o All clearances to combustibles have been met o Al...

Страница 52: ...to the battery bay in the transmitter Correctly align polarity 2 Insert the four 4 provided AA batteries into the wall switch battery bay behind the wall switch plate Correctly align polarity 3 On the...

Страница 53: ...n OffThe Appliance Press the ON OFF Key on the Remote The Remote LCD display will only show the room temperature and Icon and the appliance burner will turn off A single beep from the Receiver confirm...

Страница 54: ...stay ignited Flame sensor obstruction Remove any obstruction near pilot igniter and flame sensor Loose pilot connections Check pilot wiring assembly is tightly secured to ignition module Low gas press...

Страница 55: ...BLACK FIRE GLASS 10 LB JAR RFG 10 VB 1 2 REFLECTIVE KRYSTALLO DIAMOND FIRE GLASS 10 LB JAR RFG 10 KD 1 2 REFLECTIVE AMBER DIAMOND FIRE GLASS 10 LB JAR RFG 10 AG Glass Media will be included with the...

Страница 56: ...Driftwood 60 Set For the 82L72 Fireplace ISF L 60LGC Western Driftwood 72 Set For the 82L96 Fireplace ISF L 72LGC Western Driftwood 96 Set For the 82L120 Fireplace ISF L 96LGC Driftwood 36 Set For the...

Страница 57: ...AR 96 LINEAR120 Burner Size Circle One 36 48 72 96 Gas Type Circle One Natural Gas Propane Fireplace Serial Number ________________________________________________________________________________ Loca...

Страница 58: ...6899 Phillips Industrial Blvd Jacksonville Florida 32256 in writing by registered mail within thirty 30 days following the discovery of the defect within the lifetime warranty period The notice shall...

Отзывы: