![Isokern 82L120 Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/isokern/82l120/82l120_installation-operation-maintenance-and-owners-manual_2093403018.webp)
18
Earthcore Industries
Isokern Maximus Linear Series Gas Fireplace
01/2020
Maximus Linear Glass Front Kit Installation
The following assembly instructions identify the parts by name, part number and the placement of each part in the assembly
process for the Glass Front Linear Fireplace.
NOTE:
At all component placements, be sure to mortar all contact surfaces with Earthcore Adhesive. Check for complete
sealing of each contact joint while assembly progresses.
1.
Apply Earthcore Adhesive to the joint between each baseplate part from the linear fireplace package. Making sure to
set each base plate in a full bed of Earthcore Adhesive on a level support surface
(Figure 9)
. See page15
for supporting
floor system. Do not set the base plate so that it is in span. Refer to pages 25-28 for part dimensions.
2.
Set the first course of the firebox side walls and back walls into place
(Figure 9).
NOTE:
It may be convenient to dry set the first course of side walls and back walls into place on the Isokern base plate
and then trace their position on the base plate with a pencil.
After outlining the dry set pieces, remove them and apply Earthcore Adhesive to the areas traced on the base plate where
the side walls and back wall are to sit. By doing this, the first layer of wall components can be set directly into Earthcore
Adhesive already applied to the proper areas on the base plate.
Backwall:
48": Part# M67
72": Part# 72, 73
96": Part# 160, 162, 73
120": Part# 73, 162, 162, 71
Sidewall:
M90B
Baseplate From Linear Box:
48": Part# M93
72": Part# M91, M91
96": Part# M92, M93, 191
120": Part# M92, M96, M93
FIGURE9