3. Quick Start 

To start work with iSocket GSM 706/707 is very simple. You need a SIM-card from a 
GSM-operator. If you have not purchased SIM-card, then do so at the nearest mobile 

operator's office. You can also use prepaid cards. 

 

Quick Start comprises three simple steps: 
 
 
1. Turn off PIN authorisation for SIM-

card. 

Insert the SIM-card into your mobile phone 
and disable PIN usage using the phone menu. 

You can find more information in the manual 
for your phone or ask assistance from the 
shop, where you purchased the mobile 
subscription. 

 

2. Insert the SIM-card into the special 
slot and push until fixed (you will hear a 
click). SIM-card orientation is shown on 
the front side of the device. 

 

Do not insert or eject the SIM-card 
on a running device! Switch off the 
device before you insert or eject 

SIM-card. 

 

 

 

 
3. Connect the iSocket to a wall socket. 

 

If you have forgotten to disable PIN 
authorisation the GSM indicator will 
start blinking rapidly. Make sure that 

PIN authorisation was turned off! 
 
If the SIM-card is not inserted 
correctly or is damaged the indicator 
POWER and OUT will signal this by 

specific blinks (see Chapter 16). 

All indicators blink three times simultaneously 
(except GSM indicator). If everything is 

functioning the POWER indicator will be green. 
GSM indicator blinks once a second during 
network search and every 3 seconds when the 
network has been found. More information 

about the indicators in Chapter 16. 
 
The device might reject some old sim cards. 
Please make sure you are using a modern sim 
card which complies with specification. 

 
The device is now ready to work! You can carry out a simple test. Connect an appliance 
to the iSocket, e.g. a desk lamp (don't forget to turn on the lamp switch). Send the 

message 

ON

 to the SIM-card number and the lamp will switch on. Send the message 

OFF

 and the lamp will turn off. 

NOTE!  

You must disable PIN-code authorisation for the SIM-card! The iSocket GSM 

706/707 will not work unless you do this. You can only disable PIN authorisation by 
using your mobile phone. Do not use SIM-cards that contain messages! Remove all 

messages from the SIM-card. If you use a prepaid card you might be need to activate it 
first with your cell phone network provider. More information is available from 
www.isocket.eu/prepaid/ 

Содержание GSM 706

Страница 1: ......

Страница 2: ...play commands associated with optional features The documentation and product are subject to change without notice The software supplied with this product is the exclusive property of Intellectronics...

Страница 3: ...nd Commands From Unauthorised Users 14 7 Measurement and Control of Temperature 15 7 1 Thermometer 15 7 2 Thermostat 15 7 3 Temperature Monitoring Notifications iSocket Temperature Notifier 16 7 4 Tem...

Страница 4: ...ecial connector Notification will be sent when it is triggered For example it could be a motion sensor an opening doors sensor fire detector gas leakage detector and many more A built in microphone al...

Страница 5: ...et manual Chapter 4 3 or reset device Chapter 15 Built in microphone Chapter 10 not available in Light model Plug to connect iSocket GSM 706 707 to the wall socket to provide power for device and for...

Страница 6: ...e shows model ISGSM706UK ISGSM707UK Socket Plug NEMA 5 15 Model Numbers ISGSM706US ISGSML706US ISGSM707US ISGSML707US The figure shows model ISGSM706US ISGSM707US Socket Plug CEE 7 5 French Model Numb...

Страница 7: ...ical network meets safety standards The product is designed for indoor use in dry area Do not use it in wet or chemically aggressive environments For example do not use it in the bathroom It is also n...

Страница 8: ...n a car that is parked in sunshine If the battery suffers overloading and or overheating the integrated protective cut off will switch off the charging discharging for safety reasons If this happens y...

Страница 9: ...n was turned off If the SIM card is not inserted correctly or is damaged the indicator POWER and OUT will signal this by specific blinks see Chapter 16 All indicators blink three times simultaneously...

Страница 10: ...ut only inform you of the value These commands are available at any time You can set up the facility to reset the configuration interval see section 5 3 Control and management commands marked Ctrl in...

Страница 11: ...lay OFF Signal Good 67dBm TEMP 25C ALARMF Disabled ALARM status No activity Time y m d h m s Ctrl TEMPERATURE Informs about temperature in the room See details in Chapter 7 TEMPERATURE 25C Ctrl RUNTIM...

Страница 12: ...device which is not advisable The device uses two methods of protection against unauthorised access Only allowing access to authorised phone numbers Authentication by password Both methods can be used...

Страница 13: ...Chapter 6 3 lists more reasons for this alternative 5 2 Password Protection The following table shows how to set a password for managing access The password must consist of 5 characters Do not use a...

Страница 14: ...successfully For this purpose we have implemented notifications of each executed command If you wish to receive execution confirmations the setting hide my number should not be activated on the phone...

Страница 15: ...ecurity list was configured see Chapter 5 1 and someone tries to execute a command no response will be received until you install SMSCONFIRMUNAUTH ON If you set ON value for this parameter then unauth...

Страница 16: ...utes after the power is switched on The temperature reading interval is 1 minute for models manufactured after July 2012 If the thermostat is enabled the first reading will occur 10 minutes after the...

Страница 17: ...NUMBER 35 8912345678 Set the number for SMS This number is used in some other cases Chapters 9 2 11 and 12 You can install up to 10 numbers Instructions how to add a number are similar to those given...

Страница 18: ...r each monitored environment The value can be decided empirically by comparing with the exact thermostat temperatures measured Command Description Response Type TEMPCAL 7 Change calibration constant f...

Страница 19: ...rm function will send alerts and sound the siren if connected because the sensors have been activated In this event the alarm function can be deactivated manually by using the hidden button Push the h...

Страница 20: ...device will not detect new sensor triggering The device will be ready to detect sensor activity no later than one minute after completion of the notification cycle If the sensor is still active at thi...

Страница 21: ...designed for switching of external electrical contacts It can switch 24VDC 2A max Connectors and sensors are not supplied with the device These can be bought directly from us or our dealer network 10...

Страница 22: ...at 18 00 SCHEDULER 17 00 6 INF Send status of iSocket every Saturday at 17 00 Status information is sent to the number specified by command ALERTNUMBER see Chapter 7 3 12 Status After Resumption of P...

Страница 23: ...ALDOUMS NO Remove UMS code for balance from memory SALDOUMS NO OK 30min SALDOUMS Information about SALDOUMS settings SALDOUMS 100 Inf 14 Version Information Command Description Response Type HARDWARE...

Страница 24: ...to GSM network MICROPHONE yellow No light Microphone is not active Lights constantly Microphone is active now Blinks every second Device is calling to somewhere for ex call alert OUT red No light Main...

Страница 25: ...th Li ion battery Store conditions 30C 50C 22F 122F for the 706 models 0C 40C 32F 104F for the 707 models with Li ion battery Important notice The 706 models can operate at low temperatures in a dry p...

Страница 26: ...at it was written correctly according to the manual Read about other potential problems below The OUT indicator reports an error blinking 4 times per second If the OUT indicator blinks 4 times per sec...

Страница 27: ...y loss Intellectronics does not guarantee that this product will provide uninterrupted operation of the controlled equipment this device is not an uninterruptible power supply UPS This product is not...

Страница 28: ...hout the express written consent of Intellectronics and any applicable third party You may not create derivative works or use any information available in this User Manual for commercial or public pur...

Отзывы: