![ISHIDA IGB-150 Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/ishida/igb-150/igb-150_service-manual_2092763042.webp)
Manual No. 085-3435-07
41/45
IGB/IGX Series (Overseas Specifications) Service Manual
4.3 Replacing and Adjusting Load Cell
Load Cell Specifications
Model Type
Rated
Capacity
Rated
Output
Input
Resistance
Output
Resistance
insulation
Resistance
IGB/X -60
LOC-ISS10-100kg
100k
g
2.0mV/V
±
5%
1500
Ω
±
10
Ω
1000
Ω
±
3
Ω
5G
Ω
IGB/X -150
LOC-ISS10-300kg
300k
g
2.0mV/V
±
5%
1500
Ω
±
10
Ω
1000
Ω
±
3
Ω
5G
Ω
1
Using an allen wrench, remove the four hexagon-headed bolts and spacers fixing the load
cell unit from the top of the base.
2
Remove the four hexagon-headed bolts and spacers from the bottom of the base.