![ISHIDA IGB-150 Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/ishida/igb-150/igb-150_service-manual_2092763024.webp)
Manual No. 085-3435-07
23/45
IGB/IGX Series (Overseas Specifications) Service Manual
Address Weight
Item
Data
112A
-
Start width
0: ±1/50 (±2%) of weighing capacity
1: ±1/25 (±4%) of weighing capacity
2: ±1/10 (±10%) of weighing capacity
3: ±1/7.5 (±13.3%) of weighing capacity
4: ±1/6 (±16.6%) of weighing capacity
5: ±1/5 (±20%) of weighing capacity
6: ±1/4 (±25%) of weighing capacity
7: ±1/3 (±33.3%) of weighing capacity
8: ±1/2 (±50%) of weighing capacity
9 and more: Invalid
112B
-
Stable/Re-stable count
0 through 15 times
113A
-
Stable/Re-stable width
n=0 through 15 (±n/10 e)
113B -
Re-stable
operation
start
width
n=0 through 15 (±n/10 e)
1
Zero point mark
0: Light at true zero
1: Light at dummy zero
2
Over-scale display
0: Blank
1:”OL”
4
Display below true zero
0: “-----------“
1: Minus numeric value
114A
8
Decimal point form
0: ”.”
1: ”,”
1
Over-scale range
0: Display upto +9e
1: Display upto +3e
2
Tare subtraction
0: Yes
1: No
4
Tare clear with ZERO key 0: No
1: Yes
114B
8
Zero supress display
(Multi Interval
specification only)
0: Yes
1: No
1
Key-in preset tare
subtraction and preset
single weight function
Preset unit weight
function
0: Yes
1: No
2
Zero tracking
0: Yes
1: No
4
Micro weight follow-up
0: Yes
1: No
115A
8
Unstable width
0: ±0.5e
1: ±20e
1
No. of PLUs and PLU
display (IGB only)
0: 10 PLUs
1: 5 PLUs
Display No
display
2 Stable
display
(IGB only)
0: “
∗
” display
1: “
▼
” cursor display
4
Weight unit cursor display 0: Always light 1: Light only when “No change”is set
115B
8 Reserved