Manual No. 085-3435-07
13/45
IGB/IGX Series (Overseas Specifications) Service Manual
2.2.2 Scale No. Table
Address
110A 110B 111A 111B
Scale No.
Specifications
Default Data
0
150kg (0.05kg/0.02kg) Multi Interval
6
C
3
8
1
60kg (0.02kg/0.01kg)
Multi Interval
2
B
3
8
2
30kg (0.01kg/0.005kg) Multi Interval
B
B
3
8
3
15kg (0.005kg/0.002kg) Multi Interval
7
C
3
8
4
6kg (0.002kg/0.001kg) Multi Interval
3
B
3
8
5
6000g (2g/1g)
Multi Interval
0
B
B
8
6
3000g (1g/0.5g)
Multi Interval
9
B
B
8
7
120kg (0.02kg)
1/6000 Single Range
6
B
2
8
8
60kg (0.01kg)
1/6000 Single Range
2
B
2
8
9
30kg (0.005kg)
1/6000 Single Range
B
B
2
8
10
15kg (0.002kg)
1/7500 Single Range
7
B
2
8
11
6kg (0.001kg)
1/6000 Single Range
3
B
2
8
12
300kg (0.1kg)
1/3000 Single Range
1
B
2
8
13
150kg (0.05kg)
1/3000 Single Range
A
8
2
8
14
60kg (0.02kg)
1/3000 Single Range
6
8
2
8
15
30kg (0.01kg)
1/3000 Single Range
2
8
2
8
16
15kg (0.005kg)
1/3000 Single Range
B
8
2
8
17
6kg (0.002kg)
1/3000 Single Range
7
8
2
8
18
6000g (2g)
1/3000 Single Range
4
8
A
8
19
3000g (1g)
1/3000 Single Range
0
8
A
8
20
150kg/60kg (0.05kg/0.02kg)
Dual Range
6
C
5
8
21
60kg/30kg (0.02kg/0.01kg)
Dual Range
2
B
5
8
22
30kg/15kg (0.01kg/0.005kg)
Dual Range
B
B
5
8
23
15kg/6kg (0.005kg/0.002kg)
Dual Range
7
C
5
8
24
6kg/3kg (0.002kg/0.001kg)
Dual Range
3
B
5
8
25
6000g/3000 (2g/1g)
Dual Range
0
B
D
8
26
3000g/1500 (1g/0.5g)
Dual Range
9
B
D
8
27
150kg/150k (0.1kg/0.05kg
Dual Range
Fishery specification
A 8 5 8
28
150kg (0.05kg)
1/3000 Single Range
Body weight specification
A 8 4 2
29
30kg (0.01kg)
1/3000 Single Range
Baby scale specification
2 8 4 2
30
300lb/150kg (1/3000)
Multi Interval
6
C
7
8
31
150lb/60kg (1/3000)
Multi Interval
2
B
7
8
32
60lb/30kg (1/3000)
Multi Interval
B
B
7
8
33
30lb/15kg (1/3000)
Multi Interval
7
C
7
8
34
15lb/6kg (1/3000)
Multi Interval
3
B
7
8
99
Individual scale settings
-
-
-
-
Note
1. By setting the Scale No., the scale will function according to default data of addresses 110 and
111.
2 The above data determines each specification, so changing the data is prohibited.
3 Data A indicates the upper position of the one-byte data, and B indicates the lower position.
Reference
Reference
Refer to “Weighing Condition Data Table” for data details.