Retail Scales
3
1.2
BC-3000
Follow the steps below to set up and calibrate the Ishida BC-3000 scale.
Do not use a screwdriver or
other metal tool to press the
switch in Step 10.
Figure 1-2. View of BC-3000 scale
Step
Action
Display
1
Turn off scale.
2
Turn on scale while depressing the 1 key. Release the 1 key after two beeps.
C00 0
3
Press the 1 key and push ENTER two times. xxxx=default values between 500 and 5000.
xxxx xxxx
4
With no weight on the weigh platter, press the ZERO key to set the initial zero point.
0 2000
5
Initial A/D value should read 2000 ± 1.
If No: Press ZERO key again; If Yes: Proceed to step 6.
0 2000
6
Place 30 lb weight on platter.
30000 32000
7
Is A/D change value within 30000 ± 2?
If NO: • Press the TARE key If YES: Proceed to step 8
• Remove weight from platter and return to step 4.
30000 32000
8
Remove weight and weigh platter from unit to perform data registration.
9
Remove white plastic screw from unit (see illustration below).
10
Press memory switch inside unit.
11
Replace the white plastic screw and the weigh platter.
12
Press the END key twice
C00 0
13
Turn scale off.
14
Turn on scale again and test the calibration by placing a known weight on the platter.
0.00 0.00 0.00
!